• NFPA 13A : 1987

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    INSPECTION, TESTING, AND MAINTENANCE OF SPRINKLER SYSTEMS

    Available format(s): 

    Superseded date:  23-07-2013

    Language(s): 

    Published date:  12-01-2013

    Publisher:  National Fire Protection Association

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Chapter 1 - General information
    1-1 Scope
    1-2 Purpose
    1-3 Definitions
    1-4 Units
    1-5 Responsibility of the owner or occupant
    1-6 Sprinkler inspection service
    Chapter 2 - Water supplies
    2-1 General
    2-2 Gravity tanks and suction tanks
    2-3 Pressure tanks
    2-4 Fire pumps
    2-5 Hydrants
    2-6 Riser flow tests
    2-7 Control valves
    2-8 Fire department connections
    2-9 Hose and hose stations
    Chapter 3 - Automatic sprinklers
    3-1 General
    3-2 Replacement sprinklers
    3-3 Automatic sprinkler replacement and testing
          program
    3-4 Sprinkler guards
    3-5 Stock of spare sprinklers
    Chapter 4 - Sprinkler system components
    4-1 General
    4-2 Piping
    4-3 Hangers
    4-4 Gages
    4-5 Water flow alarm devices
    4-6 Notification to supervisory service
    4-7 Wet systems - alarm valves
    4-8 Dry systems - dry valves, accelerators,
          exhausters
    4-9 Air compressor
    4-10 Air maintenance device
    4-11 Quick-opening devices (accelerator
          or exhauster)
    4-12 Deluge, preaction, and automatic on-off
          preaction systems
    Chapter 5 - Flushing
    5-1 Flushing
    5-2 Types of obstruction material
    5-3 Preventing entrance of obstructive material
    5-4 Conditions showing need for investigation
    5-5 Precautions
    5-6 Investigation procedure
    5-7 Test - flushing mains
    5-8 Testing sprinkler systems
    5-9 Dry-pipe systems
    5-10 Wet systems
    5-11 Outside sprinklers for protection against
          exposure fires
    5-12 Flushing procedure
    5-13 Private fire service mains
    Chapter 6 - Impairments
    6-1 General
    6-2 Impairment coordination
    6-3 Preplanned impairment programs
    6-4 Emergency impairments
    6-5 Restoring systems to service after disuse
    6-6 Sprinkler system alterations
    Chapter 7 - Fire records
    7-1 Protection records
    7-2 Valve tag systems
    7-3 Inspection records
    Appendix
    Index

    Abstract - (Show below) - (Hide below)

    Includes practical advice for managers and property owners on how to keep sprinkler systems in proper operating condition. Coverage includes definitions, pressure tanks, control valves, fire department connections, fire pumps, replacement sprinklers, stock of spare sprinklers, water flow alarm devices, types of obstructive material, investigation procedure, air compressor, air maintenance device, and private fire service mains.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Fire Protection Association
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFPA 912 : 1993 FIRE PROTECTION IN PLACES OF WORSHIP
    NFPA 231E : 1996 STORAGE OF BALED COTTON
    NFPA 72H : 1988 TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
    NFPA 19911 : 1991 FIRE PROTECTION OF MUSEUMS AND MUSEUM COLLECTIONS
    NFPA 913 : 1992 HISTORIC SITES AND STRUCTURES
    NFPA 81 : 1986 FUR STORAGE, FUMIGATION AND CLEANING

    Standards Referencing This Book - (Show below) - (Hide below)

    NFPA 22 : 2013 WATER TANKS FOR PRIVATE FIRE PROTECTION
    NFPA 72B : 1986 INSTALLATION, MAINTENANCE, AND USE OF AUXILIARY PROTECTIVE SIGNALING SYSTEMS
    ASTM E 380 : 1993 Standard Practice for Use of the Internation System of Units (SI) (the Modernized Metric System) (Withdrawn 1997)
    NFPA 21 : 1982 OPERATION AND MAINTENANCE OF STEAM FIRE PUMPS
    NFPA 1962 : 2013 CARE, USE, INSPECTION, SERVICE TESTING, AND REPLACEMENT OF FIRE HOSE, COUPLINGS, NOZZLES, AND FIRE HOSE APPLIANCES
    NFPA 71 : 1989 INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE
    NFPA 231D : 1998 STORAGE OF RUBBER TIRES
    NFPA 33 : 2016 SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS
    NFPA 24 : 2016 INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES
    NFPA 14 : 2016 INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
    NFPA 231 : 1998 GENERAL STORAGE
    NFPA 13E : 2015 FIRE DEPARTMENT OPERATIONS IN PROPERTIES PROTECTED BY SPRINKLER AND STANDPIPE SYSTEMS
    NFPA 26 : 1988 SUPERVISION OF VALVES CONTROLLING WATER SUPPLIES
    NFPA 231C : 1998 RACK STORAGE OF MATERIALS
    NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
    NFPA 307 : 2016 CONSTRUCTION AND FIRE PROTECTION OF MARINE TERMINALS, PIERS, AND WHARVES
    NFPA 72A : 1987 INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS
    NFPA 20 : 2016 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective