NFPA 80:2025
Current
The latest, up-to-date edition.
Standard for Fire Doors and Other Opening Protectives
Hardcopy
English
18-09-2024
Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Retroactivity.
1.5 Equivalency.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications.
2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
Chapter 4 General Requirements
4.1 General.
4.2 Listed and Labeled Products.
4.3 Oversized Doors.
4.4 Glazing Material in Fire Doors.
4.5 Fire Resistance Glazing in Doors and Windows.
4.6 Classification of Hardware for Fire Doors.
4.7 Actuation Devices for Fire Doors and Fire Windows.
4.8 Supporting Construction.
4.9 Noncombustible Material.
Chapter 5 Inspection, Testing, and Maintenance
5.1 General.
5.2 Inspection and Testing.
5.3 Retrofit Operators.
5.4 Performance-Based Option.
5.5 Maintenance.
Chapter 6 Swinging Doors with Builders Hardware
6.1 Doors.
6.2 Supporting Construction.
6.3 Openings.
6.4 Assembly Components.
6.5 Application, Installation, and Adjustment.
Chapter 7 Swinging Doors with Fire Door Hardware
7.1 Doors.
7.2 Supporting Construction.
7.3 Openings.
7.4 Assembly Components.
7.5 Applied Metals.
Chapter 8 Horizontally Sliding Doors
8.1 Doors.
8.2 Supporting Construction.
8.3 Openings. (Reserved)
8.4 Assembly Components.
Chapter 9 Special-Purpose Horizontally Sliding Accordion or Folding Doors
9.1 Doors.
9.2 Supporting Construction.
9.3 Clearances.
9.4 Assembly Components.
Chapter 10 Vertically Sliding Fire Doors
10.1 Doors.
10.2 Supporting Construction.
10.3 Clearances.
10.4 Assembly Components.
Chapter 11 Rolling Steel Doors
11.1 Doors.
11.2 Supporting Construction.
11.3 Openings.
11.4 Assembly Components.
11.5 Weather Protection.
Chapter 12 Fire Shutters
12.1 Types.
12.2 Requirements.
12.3 Weather Protection.
Chapter 13 Service Counter Fire Doors
13.1 Doors.
13.2 Supporting Construction.
13.3 Counters.
13.4 Automatic Closing.
Chapter 14 Hoistway Doors for Elevators and Dumbwaiters
14.1 Doors.
14.2 Types of Doors.
14.3 Hoistway Door Vision Panels.
14.4 Door Operation.
Chapter 15 Chute Doors
15.1 Doors.
15.2 Chute Discharge Doors.
15.3 Chute Intake Doors.
Chapter 16 Access Doors
16.1 Doors.
16.2 Types of Doors.
Chapter 17 Horizontal Fire Door Assemblies
17.1 Doors.
Chapter 18 Fire Windows
18.1 Windows.
18.2 Glazing Material.
18.3 Types of Windows.
18.4 Installation.
18.5 Closing Devices.
Chapter 19 Glass Block Assemblies
19.1 General.
19.2 Installation.
Chapter 20 Installation, Testing, and Maintenance of Dampers
20.1 General.
20.2 Installation.
20.3 Inspection, Testing, and Maintenance.
Chapter 21 Fabric Fire Safety Curtains
21.1 General.
21.2 Fabric Fire Safety Curtain Components.
21.3 Installation.
21.4 Fire Safety Curtain Assemblies.
21.5 Supporting Construction.
21.6 Rigging and Lifting Equipment.
21.7 Operation of the Fire Safety Curtain Assembly.
21.8 Acceptance Testing.
21.9 Care and Maintenance.
Chapter 22 Fire Protective Curtain Assemblies
22.1 General.
22.2 Mounting of Fire Protective Curtain Assemblies.
22.3 Assembly Components.
22.4 Power Operators.
22.5 Installation.
22.6 Inspection, Testing, and Maintenance.
22.7 Acceptance Testing.
22.8 Periodic Inspection and Testing.
22.9 Maintenance.
Annex A Explanatory Material
Annex B Fire Doors: Protection of Conveyor Openings
Annex C Illustration of Types of Fire Window Components
Annex D Fire Door and Fire Window Classifications
Annex E Surface Attachments to Swinging Door Faces
Annex F Door Hardware Locations
Annex G Types of Door Construction
Annex H Special Purpose Doors
Annex I Radiant Heat Transfer
Annex J Performance-Based Option for the Inspection, Testing, and Maintenance of Fire Door Assemblies
Annex K General Information About Fire Doors
Annex L Informational References
This standard regulates the installation and main‐ tenance of assemblies and devices used to protect openings in walls, floors, and ceilings against the spread of fire and smoke within, into, or out of buildings.
DocumentType |
Standard
|
Pages |
112
|
PublisherName |
National Fire Protection Association
|
Status |
Current
|
Supersedes |
NFPA 701:2023 | Standard Methods of Fire Tests for Flame Propagation of Textiles and Films |
NFPA 105:2022 | Standard for Smoke Door Assemblies and Other Opening Protectives |
NFPA 90A:2024 | Standard for the Installation of Air-Conditioning and Ventilating Systems |
ASTM D 5034 : 2021 | Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) |
NFPA 72:2025 | National Fire Alarm and Signaling Code |
NFPA 288:2022 | Standard Methods of Fire Tests of Horizontal Fire Door Assemblies Installed in Horizontal Fire Resistance–Rated Assemblies |
NFPA 257:2022 | Standard on Fire Test for Window and Glass Block Assemblies |
NFPA 253:2023 | Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source |
ASTM D 4157 : 2013 : R2022 | Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.