FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS
16-03-2019
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions
3.2 Symbols and abbreviations
4 Classes of reaction to fire performance
5 Test methods
5.1 Non-combustibility test (prEN ISO 1182)
5.2 Calorific potential test (prEN ISO 1716)
5.3 Single burning item test (EN 13823)
5.4 Ignitability test (prEN ISO 11925-2)
5.5 Determination of the burning behaviour of
floorings, using a radiant heat source
(prEN ISO 9239-1)
6 Principles for testing and specimen preparation
6.1 General requirements for specimen preparation
6.2 Specific requirements for non-combustibility
and calorific potential testing
6.3 Specific requirements for the single burning
item test and the test for the determination
of the burning behaviour of floorings, using
a radiant heat source
7 Number of tests for classification
8 Testing of construction products, excluding floorings
8.1 Class E
8.2 Classes D, C, B
8.3 Classes A2, A1
8.3.1 Homogenous products
8.3.2 Non-homogeneous products
8.3.3 Class A2 products
8.4 Additional classification s1, s2, s3 for smoke
production
8.5 Additional classification d0, d1, d2 for flaming
droplets/particles
9 Testing of floorings
9.1 Class E[fl]
9.2 Classes D[fl], C[fl], B[fl]
9.3 Classes A2[fl], A1[fl]
9.3.1 Homogeneous products
9.3.2 Non-homogeneous products
9.3.3 Class A2[fl] products
9.4 Additional classification s1, s2 for smoke
production
10 Classification criteria for construction products,
excluding floorings
10.1 General
10.2 Class F
10.3 Class E
10.4 Class D
10.5 Class C
10.6 Class B
10.7 Class A2
10.7.1 General
10.7.2 Homogeneous products
10.7.3 Non-homogeneous products
10.8 Class A1
10.8.1 Homogeneous products
10.8.2 Non-homogeneous products
10.9 Additional classifications s1, s2, s3 for smoke
production
10.9.1 General
10.9.2 s1
10.9.3 s2
10.9.4 s3
10.10 Additional classifications d0, d1, d2 for flaming
droplets and/or particles
10.10.1 Products classified A2, B, C, D
10.10.2 Products classified E
11 Classification criteria for floorings
11.1 General
11.2 Class F[fl]
11.3 Class E[fl]
11.4 Class D[fl]
11.5 Class C[fl]
11.6 Class B[fl]
11.7 Class A2[fl]
11.7.1 General
11.7.2 Homogeneous products
11.7.3 Non-homogeneous products
11.8 Class A1[fl]
11.8.1 Homogeneous products
11.8.2 Non-homogeneous products
11.9 Additional classifications s1, s2 for smoke
production
11.9.1 General
11.9.2 s1
11.9.3 s2
12 Presentation of classification
12.1 Construction products, excluding floorings
12.2 Floorings
13 Field of application of the classification
14 Classification report
14.1 General
14.2 Content and format
Annex A (informative) Background information for the
application of the Commission Decision of 8
February 2000 implementing Council Directive
89/106 EEC as regards the classification of the
reaction to fire performance of construction
Products
A.1 General
A.2 Assumptions
A.3 Reference fire situations
A.3.1 Reference fore situations for construction
products except floorings
A.3.2 Reference fire situations for flooring
A.4 Relationship between classes and reference fire
situations
A.4.1 General
A.4.2 For all construction products excluding floorings
A.4.3 For floorings
Annex B (normative) Reaction to fire classification
report
B.1 General layout
B.2 Introduction
B.3 Details of classified product
B.3.1 Nature and end use application
B.3.2 Description
B.4 Test reports and test results in support of this
classification
B.4.1 Test reports
B.4.2 Test results for construction products
except floorings
B.4.3 Test results for floorings
B.5 Classification and direct field of application
B.5.1 Reference and direct field of application
B.5.2 Classification
B.5.3 Field of application
B.6 Limitations
B.6.1 Restrictions
B.6.2 Warning
Bibliography
Gives the reaction to fire classification procedure for all construction products, including those incorporated within building elements.
DevelopmentNote |
2007 Edition Re-Issued in December 2009 & incorporates AMD 1 2009. (12/2009)
|
DocumentType |
Standard
|
PublisherName |
Norwegian Standards (Norges Standardiseringsforbund)
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NF EN 13501-1 : 2007 + A1 2013 | Identical |
SN EN 13501-1 : 2007 + A1 2009 | Identical |
UNI EN 13501-1 : 2009 | Identical |
BS EN 13501-1 : 2007 | Identical |
DIN EN 13501-1:2010-01 | Identical |
NEN EN 13501-1 : 2007 + A1 2009 | Identical |
ONORM EN 13501-1 : 2009 | Identical |
NBN EN 13501-1 : 2007 + A1 2010 | Identical |
UNE-EN 13501-1:2007 | Identical |
I.S. EN 13501-1:2007 | Identical |
EN 13501-1:2007+A1:2009 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.