    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative References
    3 Definitions
      3.1 System and its constituent parts
      3.2 Adjusting, control and safety devices
      3.3 Operation of the system
      3.4 Gases
      3.5 Conditions of operation and measurement
      3.6 Country of destination
    4 Classification of Systems
      4.1 Classification according to the nature of the gases
          used (categories)
      4.2 Classification according to the gases capable of
          being used
      4.3 Classification according to the mode of evacuation of
          the combustion products
    5 Constructional Requirements
      5.1 General
      5.2 Requirements for adjusting, control and safety devices
      5.3 Ignition devices
      5.4 Main burners
      5.5 Pressure test points
      5.6 Injectors
    6 Operational Requirements
      6.1 Soundness
      6.2 Heat inputs
      6.3 Limiting temperatures
      6.4 Ignition, cross-lighting and flame stability
      6.5 Pressure governor
      6.6 Combustion
      6.7 Prolonged performance
      6.8 Measurement of oxides of Nitrogen, NO[x]
    7 Test methods
      7.1 General
      7.2 Construction and design
      7.3 Safety of operation
    8 Marking and instructions
      8.1 Marking of the system and the packaging
      8.2 Instructions
      8.3 Presentation
    Annex A (informative) System H
    Annex B (informative) National situations
    Annex C (informative) Equivalence rules
    Annex D (informative) Calculation of the mass flow rate
            of flue gases
    Annex E (informative) Identification of the type of gas
            in use in the various countries
    Annex F (normative) Special national conditions
    Annex G (informative) Example of calculation of the
            weighting factors for a system with several
            rates
    Annex H (informative) Calculations of conversions of NO[x]
    Annex I (informative) National situations of countries
            whose national bodies are CEN associate members
    Annex ZA (informative) Clauses of this European Standard
             addressing essential requirements or other
             provisions of EU Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    Specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube systems incorporating two or more burner units with each burner under the control of an automatic burner control system, and operated by a single fan providing a single flue outlet, called system H and referred to in the body of the text as the "system". Applicable to Type B[22] systems intended for use in other than domestic dwellings, in which the supply of combustion air and the evacuation of the products of combustion is achieved by mechanical means. Applicable only to such systems that have fully pre-mixed gas/air burners. Applicable to systems which are intended to be type tested.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Norwegian Standards (Norges Standardiseringsforbund)
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective