• There are no items in your cart

ONORM EN 12067-2 : 2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

GAS/AIR RATIO CONTROLS FOR GAS BURNERS AND GAS BURNING APPLIANCES - PART 2: ELECTRONIC TYPES

Superseded date

19-07-2023

Published date

12-01-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
  3.1 electronic gas/air ratio control (electronic GARC)
  3.2 electronic control box (ECB)
  3.3 actuator
  3.4 sensor
  3.5 combustion process
  3.6 defined safe state
  3.7 fault tolerating time
  3.8 safety shut-down
  3.9 lock-out
       3.9.1 non-volatile lock-out
       3.9.2 volatile lock-out
  3.10 abnormal operation
  3.11 form closure construction
4 Classification
5 Units of measurement and test conditions
6 Construction requirements
  6.1 General
  6.2 Mechanical requirements
       6.2.1 General
       6.2.2 Special requirements for electromechanical
             actuators with position feed-back sensors
  6.3 Electrical equipment
       6.3.1 General
       6.3.2 Class of protection
       6.3.3 Electronics and software
7 Functional requirements
  7.1 General
  7.2 Burner control interface
  7.3 Safety shut-down initiated by the electronic GARC
  7.4 Start-up sequence
  7.5 Preset/predefined range
  7.6 Restart from defined safe state
  7.7 Accuracy requirements
       7.7.1 General
       7.7.2 Sensor(s) and actuators
       7.7.3 Repeatability
  7.8 Protection against internal faults
       7.8.1 Failure modes of components
       7.8.2 Safety class
  7.9 Information to be supplied by the manufacturer
  7.10 Documentation
  7.11 Assessment
8 Protection against environmental influences
  8.1 General
  8.2 Test conditions
  8.3 Performance tests
       8.3.1 At ambient temperature
       8.3.2 At low temperature
       8.3.3 At high temperature
  8.4 Void
  8.5 Endurance
       8.5.1 General
       8.5.2 Vibration test
       8.5.3 Humidity
  8.6 EMC-requirements
       8.6.1 General
       8.6.2 Supply voltage variations
       8.6.3 Supply voltage interruptions or decreases
       8.6.4 Supply frequency variations
       8.6.5 Surge immunity
       8.6.6 Electrical fast transient burst
       8.6.7 Electromagnetic conducted and radiated
             disturbances induced by radio-frequency fields
       8.6.8 Electrostatic discharge immunity
9 Marking and installation
  9.1 Marking
  9.2 Installation and operating instructions
  9.3 Warning note
Annex A (informative) Approval path for the electronic GARC
Annex B (normative) Manufacturer's declaration for sensors,
                       actuators and repeatability
Annex C (normative) Special requirements for single position
                       feed-back potentiometers in electromechanical
                       actuators
Annex ZA (informative) Clauses of this European Standard addressing
                       essential requirements or other provisions of
                       EU Directives

Describes the safety, construction and performance requirements for electronic gas/air ratio control systems (GARCs) intended for use with gas burners and gas burning appliances.

DocumentType
Standard
PublisherName
Osterreichisches Normungsinstitut/Austrian Standards
Status
Superseded
SupersededBy

ONORM EN 15502-1 : 2015 GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS
OVE/ONORM EN 50465 : 2015 GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW
ONORM EN 746-2 : 2011 INDUSTRIAL THERMOPROCESSING EQUIPMENT - PART 2: SAFETY REQUIREMENTS FOR COMBUSTION AND FUEL HANDLING SYSTEMS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.