1 Scope
2 Normative references
3 Definitions
      3.1 Principle Area (PA)
      3.2 Total Area (TA)
      3.3 Reference area
      3.4 Grid points for measurement and calculation
4 General principles of the lighting installation
      4.1 Reference grid for calculation and measurement
             4.1.1 Grid size for calculation and
                      measurements for particular sports
             4.1.2 Grid size for calculation and
                      measurements for multi-sports
                      facilities
             4.1.3 Application
      4.2 Measuring equipment
      4.3 Measurement record
      4.4 Tolerated differences
      4.5 Maintenance
      4.6 Spectator area lighting
      4.7 Safety for participants and the continuation of
             an event in case of lighting failure
             4.7.1 Safety lighting for participants
             4.7.2 Continuation of a sport
      4.8 Glare restriction
             4.8.1 Indoor
             4.8.2 Outdoor
      4.9 Surface colours and reflection properties
5 Requirements for the lighting of sports most practised
      in Europe
      5.1 General requirements
      5.2 Requirements per sport
      5.3 Specific requirements for colour television and
             film recording
             5.3.1 Vertical illuminance
             5.3.2 Level of vertical illuminance
             5.3.3 Uniformity of vertical illuminance
                      5.3.3.1 Uniformity on planes facing a
                                 side-line or a fixed main
                                 camera position
                      5.3.3.2 Uniformity on vertical planes
                                 at a grid point
             5.3.4 Relation between horizontal and vertical
                      illuminance
             5.3.5 Uniformity of horizontal illuminance
             5.3.6 Colour temperature of the lighting
             5.3.7 Colour rendering of the lighting
             5.3.8 Light level on surrounding spectators'
                      areas
Annex A (normative) Tables of requirements
Annex B (informative) A-deviation
Annex C (informative) Bibliography

Covers indoor and outdoor lighting for sports events mainly held in Europe. Provides lighting values for control and design of installations in terms of uniformity, colour properties, illuminances and glare restriction of light sources. Also gives procedures for measuring these values. For glare limitation, it outlines location restriction of luminaires for specific applications.

Committee
TC 047
DevelopmentNote
Supersedes ONORM S 4205. (03/2005)
DocumentType
Standard
PublisherName
Osterreichisches Normungsinstitut/Austrian Standards
Status
Withdrawn
SupersededBy

Standards Relationship
EN 12193:2018 Identical
I.S. EN 12193:2007 Identical
SN EN 12193 : 2008 Identical
NF EN 12193 : 2008 Identical
EN 12193:2007 Identical
UNI EN 12193 : 2008 Identical
NBN EN 12193 : 2008 Identical
NEN EN 12193 : 2008 Identical
BS EN 12193:2007 Identical
NS EN 12193 : 2007 Identical
UNE-EN 12193:2009 Identical
DIN EN 12193:2008-04 Identical

ONORM S 4740 : 2013 ARTIFICIAL CLIMBING STRUCTURES - SUPPLEMENTARY NATIONAL PROVISIONS TO ONORM EN 12572-1 AND ONORM EN 12572-2
ONORM EN 12464-1 : 2011 LIGHT AND LIGHTING - LIGHTING OF WORK PLACES - PART 1: INDOOR WORK PLACES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.