ONORM EN 14593-1 : 2005
Current
The latest, up-to-date edition.
RESPIRATORY PROTECTIVE DEVICES - COMPRESSED AIR LINE BREATHING APPARATUS WITH DEMAND VALVE - PART 1: APPARATUS WITH A FULL FACE MASK - REQUIREMENTS, TESTING, MARKING
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and pictograms
4 Description
5 Requirements
5.1 General
5.2 Ergonomics
5.3 Materials
5.4 Water immersion
5.5 Cleaning and disinfecting
5.6 Practical performance
5.7 Connections
5.8 Compressed air line breathing apparatus used with
self-contained breathing apparatus - switch over
device
5.9 Body harness or belt
5.10 Performance requirements after storage
5.11 Flammability
5.12 Resistance to pressure
5.13 Mobile high pressure air supply systems
5.14 Warning devices for mobile high pressure air supply
systems
5.15 Compressed air supply tube
5.16 Breathing hose
5.17 Lung governed demand valve
5.18 Adjustable parts
5.19 Full face masks
5.20 Inward leakage
5.21 Inhalation and exhalation valves
5.22 Breathing resistance
5.23 Carbon dioxide content of inhalation air
5.24 Leaktightness
6 Testing
6.1 General
6.2 Water immersion
6.3 Visual inspection
6.4 Practical performance
6.5 Strength of connections to facepiece, demand valve,
medium pressure connecting tube and breathing hose
6.6 Resistance to collapse of breathing hose
6.7 Strength of compressed air supply tube, body harness
and couplings
6.8 Storage conditioning
6.9 Flammability
6.10 Pressure relief valve
6.11 Resistance to kinking of compressed air supply tube
6.12 Resistance to collapse of compressed air supply tube
6.13 Heat resistance of compressed air supply tube
6.14 Inward leakage
6.15 Tests for lung-governed demand valve
6.16 Determination of carbon dioxide content of the
inhalation air
6.17 Testing of audible warning device
6.18 Switch over device
7 Marking
8 Information supplied by the manufacturer
Annex A (normative) Static and dynamic pressure for apparatus
with thread connector in accordance with
EN 148-3
Annex B (informative) Marking
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements
of EU Directive 89/686/EEC (PPE)
Describes minimum requirements for compressed air line breathing apparatus with demand valve for use with a full face mask as a respiratory protective device.
DevelopmentNote |
Supersedes ONORM EN 139. (12/2005)
|
DocumentType |
Standard
|
PublisherName |
Osterreichisches Normungsinstitut/Austrian Standards
|
Status |
Current
|
Standards | Relationship |
DIN EN 14593-1:2005-07 | Identical |
UNE-EN 14593-1:2005 | Identical |
NF EN 14593-1 : 2005 | Identical |
UNI EN 14593-1 : 2005 | Identical |
I.S. EN 14593-1:2005 | Identical |
NS EN 14593-1 : 1ED 2005 | Identical |
NBN EN 14593-1 : 2005 | Identical |
BS EN 14593-1:2005 | Identical |
SN EN 14593-1 : 2005 | Identical |
EN 14593-1:2018 | Identical |
EN 148-3:1999 | Respiratory protective devices - Threads for facepieces - Part 3: Tread connection M 45 x 3 |
EN 12021:2014 | Respiratory equipment - Compressed gases for breathing apparatus |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN ISO 8031:2009 | Rubber and plastics hoses and hose assemblies - Determination of electrical resistance and conductivity (ISO 8031:2009) |
EN 132:1998 | Respiratory protective devices - Definitions of terms and pictograms |
EN 13274-3:2001 | Respiratory protective devices - Methods of test - Part 3: Determination of breathing resistance |
EN 134:1998 | Respiratory protective devices - Nomenclature of components |
EN 13274-4:2001 | Respiratory protective devices - Methods of test - Part 4: Flame tests |
EN 13274-6:2001 | Respiratory protective devices - Methods of test - Part 6: Determination of carbon dioxide content of the inhalation air |
EN 13274-1:2001 | Respiratory protective devices - Methods of test - Part 1: Determination of inward leakage and total inward leakage |
EN 137:2006 | Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with full face mask - Requirements, testing, marking |
EN 148-2:1999 | Respiratory protective devices - Threads for facepieces - Part 2: Centre thread connection |
EN 13274-2:2001 | Respiratory protective devices - Methods of test - Part 2: Practical performance tests |
EN 402:2003 | Respiratory protective devices - Lung governed demand self-contained open-circuit compressed air breathing apparatus with full face mask or mouthpiece assembly for escape - Requirements, testing, marking |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.