PD CEN/TS 16835-1:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Molecular in vitro diagnostic examinations. Specifications for pre-examination processes for venous whole blood Isolated cellular RNA
Hardcopy , PDF
08-04-2019
English
31-07-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General considerations
5 Outside the laboratory
6 Inside the laboratory
Annex A (informative) - Impact of preanalytical
workflow steps on venous whole blood
cellular RNA profiles
Annex B (informative) - Influence of blood storage
temperature on blood cellular RNA profiles
Bibliography
Provides specimens collected by venous whole blood collection tubes.
Committee |
CH/212
|
DocumentType |
Standard
|
Pages |
0
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
This Technical Specification recommends the handling, documentation and processing of venous whole blood specimens intended for cellular RNA analysis during the preanalytical phase before a molecular assay is performed. This Technical Specification covers specimens collected by venous whole blood collection tubes. This Technical Specification is applicable to molecular in vitro diagnostic examinations (e.g. in vitro diagnostic laboratories, laboratory customers, in vitro diagnostics developers and manufacturers, institutions and commercial organizations performing biomedical research, biobanks, and regulatory authorities).
Blood cellular RNA profiles can change significantly after collection. Therefore, special measures need to be taken to secure good quality blood samples for cellular RNA analysis and storage.
Different dedicated measures need to be taken for stabilizing blood cell free circulating RNA and RNA in exosomes circulating in blood, which are not described in this Technical Specification.
Different dedicated measures need to be taken for collecting, stabilizing, transporting and storing capillary blood as well as for collecting and storing blood by paper based technologies. These are not described in this Technical Specification.
RNA in pathogens present in blood is not covered by this Technical Specification.
Standards | Relationship |
CEN/TS 16835-1:2015 | Identical |
ISO 22174:2005 | Microbiology of food and animal feeding stuffs — Polymerase chain reaction (PCR) for the detection of food-borne pathogens — General requirements and definitions |
ISO 15189:2012 | Medical laboratories — Requirements for quality and competence |
EN ISO 22174:2005 | Microbiology of food and animal feeding stuffs - Polymerase chain reaction (PCR) for the detection of food-borne pathogens - General requirements and definitions (ISO 22174:2005) |
ISO 15190:2003 | Medical laboratories Requirements for safety |
ISO Guide 30:2015 | Reference materials — Selected terms and definitions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.