PD CISPR/TR 30-2:2012
Current
The latest, up-to-date edition.
Test method on electromagnetic emissions Electronic control gear for discharge lamps excluding fluorescent lamps
Hardcopy , PDF
English
30-09-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Presumption of compliance
4 Test method
5 Reference luminaire
6 Marking
7 Guidance for luminaire design
Annex A (informative) - Mounting and
wiring schemes
Defines with the aid of reference luminaires, an independent method by which the radio disturbance characteristics of built-in electronic control gear for discharge (excluding fluorescent) lamp luminaires with protection classes I and/or II may be compared against the requirements of CISPR 15.
Committee |
GEL/210
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This part of CISPR 30, which is a technical report, details with the aid of reference luminaires, an independent method by which the radio disturbance characteristics of built-in electronic control gear for discharge (excluding fluorescent) lamp luminaires with protection classes I and/or II may be compared against the requirements of CISPR 15. The scope of the part is limited to electronic lamp control gear with an output power (lamp power) up to and including 150 W.
Independent electronic lamp control gears are not covered by this technical report; they are within the scope of CISPR 15.
Standards | Relationship |
CISPR TR 30-2:2012 | Identical |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |