PD CLC/TR 50173-99-3:2012
Current
The latest, up-to-date edition.
Information technology. Generic cabling systems Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications
Hardcopy , PDF
English
30-04-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Cabling infrastructure
5 Components
6 Implementation
Annex A (informative) - Mode of television
distribution
Annex B (informative) - Assessment of Grade 3
infrastructures
Bibliography
Provides a grading system applicable to telecommunications cabling within homes which provides a range of implementation solutions to support both non-simultaneous and simultaneous provision of applications.
Committee |
TCT/7
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Technical Report describes a grading system applicable to telecommunications cabling within homes which provides a range of implementation solutions to support both non-simultaneous and simultaneous provision of applications incorporating: a cabling structure in accordance with, but less complex than that of, EN 50173-4 and with defined connecting hardware pin assignment for certain applications; components meeting or exceeding the requirements of EN 50173-4; shorter cabling channels than those specified in EN 50173-4. Safety (electrical safety and protection, optical power, fire, etc.) and electromagnetic compatibility (EMC) requirements are outside the scope of this Technical Report and are covered by standards and regulations. However information given in this Technical Report may be of assistance in meeting these standards and regulations.
Standards | Relationship |
CLC/TR 50173-99-3:2012 | Identical |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
EN 60603-7-7:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
EN 50441-2:2012 | Cables for indoor residential telecommunication installations - Part 2: Screened cables - Grade 1 |
EN 50288-2-1:2013 | Multi-element metallic cables used in analogue and digital communication and control - Part 2-1: Sectional specification for screened cables characterised up to 100 MHz - Horizontal and building backbone cables |
EN 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
IEC 60603-7-71:2010 | Connectors for electronic equipment - Part 7-71: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 1 000 MHz |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 50117-2-3:2004/A2:2013 | COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
IEC 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
EN 60603-7-3:2010 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz |
PREN 50174-3 : DRAFT 2012 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 50288-4-1:2013 | Multi-element metallic cables used in analogue and digital communication and control - Part 4-1: Sectional specification for screened cables characterised up to 600 MHz - Horizontal and building backbone cables |
EN 50117-2-5:2004/A2:2013 | COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
EN 60603-7-51:2010 | Connectors for electronic equipment - Part 7-51: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz |
EN 50441-4:2012 | Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3 |
IEC 61169-24:2009 | Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 Ω cable networks (type F) |
EN 60603-7-41:2010 | Connectors for electronic equipment - Part 7-41: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
EN 60728-1:2014 | Cable networks for television signals, sound signals and interactive services - Part 1: System performance of forward paths |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 60603-7-3:2010 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz |
EN 50117-2-4 : 2004 AMD 2 2013 | COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
EN 60603-7-71 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-71: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
IEC 60603-7-41:2010 | Connectors for electronic equipment - Part 7-41: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz |
EN 50441-1:2012 | Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1 |
EN 50288-3-1:2013 | Multi-element metallic cables used in analogue and digital communication and control - Part 3-1: Sectional specification for unscreened cables characterised up to 100 MHz - Horizontal and building backbone cables |
EN 61169-2:2007 | Radio-frequency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52 |
EN 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
EN 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEEE 802.3AT : 2009 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS - AMENDMENT 3: DATA TERMINAL EQUIPMENT (DTE) POWER VIA THE MEDIA DEPENDENT INTERFACE (MDI) ENHANCEMENTS |
IEC 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
CLC/TR 50173-99-2:2010 | Information technology - Implementation of BCT applications using cabling in accordance with EN 50173-4 |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
IEC 60603-7-7:2010 | Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
IEC 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
EN 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 60728-1:2014 | Cable networks for television signals, sound signals and interactive services - Part 1: System performance of forward paths |
IEC 60603-7-51:2010 | Connectors for electronic equipment - Part 7-51: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz |
IEC 61169-2:2007 | Radio-frenquency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52 |
EN 61169-24:2009 | Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F) |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.