PD CLC/TR 50484:2009
Current
The latest, up-to-date edition.
Recommendations for shielded enclosures
Hardcopy , PDF
English
31-07-2010
1 Scope
2 Normative references
3 Definitions
4 General
5 Shielding
Bibliography
Provides guidance to the selection of the shielding materials and components.
Committee |
GEL/210
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Technical Report applies to shielded enclosures used for EMC testing which are to be validated according to the EN 50147 series of standards and the corresponding international standards. The object of this report is to give guidance to the selection of the shielding materials and components. The frequency range for this document is 10 kHz to 40 GHz.
Standards | Relationship |
CLC/TR 50484:2009 | Identical |
EN 50147-1:1996 | Anechoic chambers - Part 1: Shield attenuation measurement |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 50147-2 : 1996 | ANECHOIC CHAMBERS - PART 2: ALTERNATIVE TEST SITE SUITABILITY WITH RESPECT TO SITE ATTENUATION |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.