• Shopping Cart
    There are no items in your cart

PD CLC/TS 50131-2-8:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors

Available format(s)

Hardcopy , PDF

Superseded date

31-12-2016

Superseded by

BS EN 50131-2-8:2016

Language(s)

English

Published date

30-06-2014

€287.48
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Standard test material
Annex B (normative) - Dimensions and requirements of
        the standardised Test Magnets
Annex C (normative) - General Testing Matrix
Annex D (normative) - Standard immunity glass pane
Annex E (normative) - Spring operated Hammer
Annex F (informative) - Example list of small tools
Annex G (normative) - Minimum performance requirements
        gross and shock integration attack tests
Annex H (normative) - Immunity test: Small objects
        hit sensitivity
Annex I (normative) - Immunity test: Hard objects
        hit sensitivity
Annex J (normative) - Immunity test: Static pressure
        sensitivity
Annex K (normative) - Immunity test: Dynamic pressure
        sensitivity
Bibliography
National Annex NA (Informative) - Text of IS1 to
                  EN 50131-2-8:2012

Pertains to shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).

Committee
GW/1/1
DocumentType
Standard
Pages
50
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).

It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).

This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance.

This Technical Specification does not include requirements for shock detectors intended for use outdoors.

A detector shall fulfil all the requirements of the specified grade.

Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions.

This Technical Specification does not apply to system interconnections.

Standards Relationship
CLC/TS 50131-2-8:2012/IS1:2014 Identical
CLC/TS 50131-2-8:2012 Identical

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60404-8-1:2015 Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60404-5:2015 RLV Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 60404-5:2015 Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.