PD IEC/TR 62627-05:2013
Current
The latest, up-to-date edition.
Fibre optic interconnecting devices and passive components Investigation on impact of contamination and scratches on optical performance of single-mode (SM) and multimode (MM) connectors
Hardcopy , PDF
English
31-10-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Abbreviations
4 Experimental methodology
5 The impact of scratches on A and RL of single-mode connectors
6 Effects of scratches on RL of MM connectors
7 Investigation of impact of contamination on optical performance
of 2,5 mm and 1,25 mm connectors
8 Correlation study between contamination and signal degradation
in single-mode APC connectors
9 Development of cleanliness specifications for single-mode, angled
physical contact MPO connectors
10 Conclusion
Annex A (informative) - The nature of particle redistribution during
series of matings/dematings
Bibliography
Reviews the extensive industry research on development of cleanliness specifications for single-mode (SM) and multimode (MM) connectors.
Committee |
GEL/86/2
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This part of IEC 62627, which is a technical report, summarizes the extensive industry research on development of cleanliness specifications for single-mode (SM) and multimode (MM) connectors. The summary of the result shows Table 1. Table 1 – Summary of the result Samples Scratch/Contamination/Defect A/RL Clause Reference SM/MM Single-fibre/multi-fibre SM PC Single-fibre Scratch RL 3 [1], [5], [6] MM PC Single-fibre Scratch RL 4 [7] SM PC Single-fibre Contamination A and RL 5 [2], [6]. [8] SM APC Single-fibre Contamination A 7 [11] SM APC Single-fibre Scratch RL 7.2 [11] SM APC Multi-fibre Contamination A and RL 8 [12]
Standards | Relationship |
IEC TR 62627-05:2013 | Identical |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
IPC 8497-1 : 0 | CLEANING METHODS AND CONTAMINATION ASSESSMENT FOR OPTICAL ASSEMBLY |
IEC 61755-3-1:2006 | Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre |