HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
Hardcopy , PDF
16-08-2024
English
27-03-2012
Committee |
PEL/36
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
This technical report is applicable to polymeric insulators whose insulating body consists of one or various organic materials. Polymeric insulators covered by this technical report include both solid core and hollow insulators. They are intended for use on overhead lines and in indoor and outdoor equipment with a rated voltage greater than 1 000 V.
The object of this technical report is:
to define the common terms used;
to give the background behind the development and use of the 5 000 h multiple stress test and the tracking wheel test;
to describe the test methods for the 5 000 h multiple stress test and the tracking wheel tests on polymeric insulators;
to describe possible acceptance or failure criteria, if applicable;
These tests, criteria and recommendations are intended to give a common basis for the 5 000h multiple stress test and the tracking wheel test when they are used for research or required as a supplementary design test. These tests are not mandatory and their use is subject to prior agreement between the interested parties.
Standards | Relationship |
IEC TR 62730:2012 | Identical |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |