PD IEC/TS 60034-27-2:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Rotating electrical machines On-line partial discharge measurements on the stator winding insulation of rotating electrical machines
Hardcopy , PDF
21-12-2023
English
31-10-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Nature of PD in rotating machines
5 Noise and disturbance
6 Measuring techniques and instruments
7 Installation of PD on-line measuring systems
8 Normalization of measurements
9 Measuring procedures
10 Visualization of measurements
11 Interpretation of on-line measurements
12 Test report
Annex A (informative) - Examples of Phase Resolved
Partial Discharge (PRPD) pattern
Bibliography
Gives a common basis for: - measuring techniques and instruments; - the arrangement of the installation; - normalization and sensitivity assessment; - measuring procedures; - noise reduction; - the documentation of results; - the interpretation of results; with respect to partial discharge on-line measurements on the stator winding insulation of non-converter driven rotating electrical machines with rated voltage of 3 kV and up.
Committee |
PEL/2
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
This part of IEC60034, which is a technical specification, provides a common basis for
measuring techniques and instruments;
the arrangement of the installation;
normalization and sensitivity assessment;
measuring procedures;
noise reduction;
the documentation of results;
the interpretation of results;
with respect to partial discharge on-line measurements on the stator winding insulation of non-converter driven rotating electrical machines with rated voltage of 3kV and up. This technical specification covers PD measur ing systems and methods detecting electrical PD signals. The same measuring devices and procedures can also be used to detect electrical sparking and ar cing phenomena.
NOTE The main differences between on-line measurements and o ff-line measurements are due to a different voltage distribution along the winding and various thermal and mechanical effects related to the operation, like vibration, contact arcing or temperature gradients between stator copper and stator iron core. Furthermore, especially for hydrogen-cooled machines the gas and the gas pressure is different for off -and on-line PD measurements.
Standards | Relationship |
IEC TS 60034-27-2:2012 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEC TS 61934:2011 | Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.