Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems
Hardcopy , PDF
English
31-05-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 List of symbols
5 Independent measurement of total acoustic
output power
6 Acoustic field measurement: equipment
7 Measurement procedure
Annex A (informative) - Rationale
Annex B (informative) - Assessment of uncertainty
in the acoustic quantities obtained by
hydrophone measurements
Annex C (informative) - Transducer and hydrophone
positioning systems
Annex D (informative) - Rationale for I[sal]
Annex E (normative) - Propagation and back-propagation
methods for field reconstruction: basic formulae
and requirements
Annex F (informative) - Propagation and back-propagation
methods for field reconstruction: examples and uses
Annex G (normative) - Planar scanning of a hydrophone
to determine acoustic output power
Annex H (informative) - Properties of water
Annex I (informative) - Propagation medium and degassing
Bibliography
Pertains to high intensity therapeutic ultrasound (HITU) devices, specifying: - relevant parameters for quantifying the field; and - measurement methods at relatively low output levels and methodology for extrapolating these to higher therapeutic level fields; and - consideration of sidelobes and pre-focal maxima; and - parameters relevant to HITU transducers of different construction and geometry, including non-focusing, focusing with or without lenses, collimated, diverging and convergent transducers, multi-element transducers, scanning transducers and multiple sources.
Committee |
EPL/87
|
DocumentType |
Standard
|
Pages |
98
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This technical specification is applicable to high intensity therapeutic ultrasound (HITU) devices, specifying:
relevant parameters for quantifying the field;
measurement methods at relatively low output levels and methodology for extrapolating these to higher therapeutic level fields;
consideration of sidelobes and pre-focal maxima;
parameters relevant to HITU transducers of different construction and geometry, including non-focusing, focusing with or without lenses, collimated, diverging and convergent transducers, multi-element transducers, scanning transducers and multiple sources.
This technical specification is intended to support the ultrasonic measurement requirements given in IEC 60601-2-62.
These specifications would have use in quality assurance, safety testing, and the standardization of communications regarding the clinical performance of HITU systems. Where possible, this technical specification incorporates specifications from other related standards.
This technical specification does not apply to the following types of devices, which are covered by other standards:
lithotripters (see IEC 61846);
surgical equipment (see IEC 61847);
physiotherapy devices (see IEC 61689).
Throughout this technical specification SI units are used. In the specification of certain parameters, such as beam-areas and intensities, it may be convenient to use decimal multiples or sub-multiples. For example, beam-area may be specified in cm2 and intensities in W/cm2 or mW/cm2.
Standards | Relationship |
IEC TS 62556:2014 | Identical |
IEC 62127-1:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
IEC 62555:2013 | Ultrasonics - Power measurement - High intensity therapeutic ultrasound (HITU) transducers and systems |
IEC 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
IEC TR 62781:2012 | Ultrasonics - Conditioning of water for ultrasonic measurements |
IEC 60601-2-62:2013 | Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
IEC 62127-3:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz |
IEC 62127-2:2007+AMD1:2013+AMD2:2017 CSV | Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz |
IEC TR 62649:2010 | Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices |
IEC TS 61949:2007 | Ultrasonics - Field characterization - In situ exposure estimation in finite-amplitude ultrasonic beams |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.