PD IEC/TS 62735-2:2016
Current
The latest, up-to-date edition.
Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices Plug and socket-outlet system for 5,2 kW
Hardcopy , PDF
English
31-01-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking
9 Checking of dimensions
10 Protection against electric shock
11 Provision for earthing
12 Terminals and terminations
13 Construction of socket-outlets
14 Construction of plugs
15 Interlocked plug and socket-outlet systems
16 Resistance to ageing, protection provided by
enclosures, and resistance to humidity
17 Insulation resistance and electric strength
18 Operation of earthing contacts
19 Temperature rise
20 Breaking capacity
21 Normal operation
22 Force necessary to withdraw the plug
23 Flexible cables and their connection
24 Mechanical strength
25 Resistance to heat
26 Screws, current-carrying parts and connections
27 Creepage distances, clearances and distances
through sealing compound
28 Resistance of insulating material to abnormal
heat and to fire
29 Resistance to rusting
Annexes
Annex AA (normative) - Standard sheets and gauges
Bibliography
Pertains to plugs and fixed socketoutlets for class I equipment with two active contacts plus an earthing contact, a rated power of 5,2 kW and a rated voltage range from 294 V to 400 V d.c.
Committee |
PEL/23
|
DevelopmentNote |
Supersedes 15/30320887 DC. (01/2017)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This clause of Part 1 is applicable except as follows:
Replacement:
Replace the first paragraph with the following:
This part of IEC 62735, which is a technical specification, applies to plugs and fixed socketoutlets for class I equipment with two active contacts plus an earthing contact, a rated power of 5,2 kW and a rated voltage range from 294 V to 400 V d.c. They are intended to power d.c. information and communication technology equipment only.
The 2,6 kW system complying with Part 1 is safely compatible with the system complying with this part as it is possible to insert the 2,6 kW plug in the 5,2 kW socket-outlet but it is not possible to insert the 5,2 kW plug into the 2,6 kW socket-outlet.
Replace the third paragraph with the following:
The maximum current for the plug and the socket-outlet is
13 A when the voltage between live contacts is 400 V d.c.
17,6 A when the voltage between live contacts is 294 V d.c.
and can rise up to 20 A when the voltage between live contacts decreases to 260 V d.c. for 10 min maximum.
Replace, in the 6th paragraph, the second dash with:
an overcurrent protection (of 17,6 A or less for each socket-outlet or multiple socketoutlet),
Standards | Relationship |
IEC TS 62735-2:2016 | Identical |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |