• Shopping Cart
    There are no items in your cart

PD IEC/TS 62743:2012

Current

Current

The latest, up-to-date edition.

Radiation protection instrumentation. Electronic counting dosemeters for pulsed fields of ionizing radiation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-2012

€257.09
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions, abbreviations
   and symbols, quantities and units
4 General test procedure
5 General requirements
6 Radiation detection requirements
7 Environmental requirements
8 Mechanical requirements
9 Electromagnetic requirements
10 Documentation
Annex A (informative) - Parameter values
        for typical workplaces where
        pulsed radiation occurs
Annex B (informative) - Parameters
        characterizing the pulsed
        radiation field
Bibliography

Pertains to all types of counting dosemeters, irrespective of the measuring quantity and the type of radiation intended to be measured.

Committee
NCE/2
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Current

This Technical Specification applies to all types of counting dosemeters, irrespective of the measuring quantity and the type of radiation intended to be measured. It ensures that a single radiation pulse can be correctly measured even if the dosemeter is in the internal state relevant for measuring background or environmental radiation. The characteristics of the dosemeter for repeated pulses is expected to be better than for one single radiation pulse with the same parameters but worse than for continuous radiation, i.e., in between of the characteristics for these two extreme conditions. This Technical Specification does not specify the characteristics of the dosemeter for repeated pulses. The Technical Specification does not apply for those types of counting dosemeters that either

  • do not have an indication or software read-out of the dose rate and the number of pulses counted,

  • convert the non-pulsed detector signal to counts by a converter, or

  • use nuclear reactions to generate long and nearly continuous secondary radiation fields which then are measured by the dosemeter using counting techniques instead of measuring the direct radiation pulse.

The pulsed radiation source is characterized by the parameters

  • radiation pulse duration, tpulse,

  • pulse peak dose rate, Hpulse, peak ,

  • dose per radiation pulse, Hpulse.

This Technical Specification considers the pulsation of the radiation field as an additional influence quantity like particle energy and direction of radiation incidence. Therefore, the tests described are additional to all the tests in the respective standards.

This technical specification describes methods to determine the characteristic parameters of the counting dosemeter. A prerequisite of the method is that the model function of the dose-meter can sufficiently be approximated by

This simplified model function should not fully describe the dosemeter but it should be valid only – maybe with effective values – for the tests in the case of a single pulse occurring when the dosemeter is in the internal state relevant for measuring background or environmental radiation, i.e., the dosemeter has not performed any specific parameter adjustment for high dose rate. In this sense this simplified model function uses effective parameters specific for pulsed radiation.

This technical specification is applicable to all types of radiation for which a suitable pulsed reference field is available and all other requirements are fulfilled.

Standards Relationship
IEC TS 62743:2012 Identical

IEC 60846-1:2009 Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors
IEC 61526:2010 Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters
ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.