PD IEC/TS 62903:2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Ultrasonics. Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method
Hardcopy , PDF
27-06-2023
English
29-01-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 General
6 Requirements of the measurement system
7 Measurement of the effective half-aperture of the
spherically curved transducer
8 Measurements of the electroacoustical parameters
and the acoustic output power
9 Measurement uncertainty
Annex A (informative) - Relation of the average
amplitude reflection coefficient on a plane
interface of water-stainless steel and the focus
half-angle for a normally incident beam of a
circular spherically curved transducer [1, 2]
Annex B (informative) - Diffraction correction
coefficient G[sf] in the free-field selfreciprocity
calibration method for circular spherically
curved transducers in water neglecting
attenuation [2, 3, 4]
Annex C (informative) - Calculation of the diffraction
correction coefficient G[sf](R/[lambda],[beta]) in the
free-field self-reciprocity calibration in a
non-attenuating medium for a circular spherically
curved transducer [2, 3, 4, 7]
Annex D (informative) - Speed of sound and attenuation
in water
Annex E (informative) - Principle of reciprocity calibration
for spherically curved transducers [2, 3, 4]
Annex F (informative) - Experimental arrangements
Annex G (informative) - Relationships between the
electroacoustical parameters used in this
application [13]
Annex H (informative) - Evaluation and expression of
uncertainty in the measurements of the radiation
conductance
Bibliography
Specifies: a) the free-field convergent spherical wave self-reciprocity method for ultrasonic transducer calibration, b) the measurement conditions and experimental procedure required to determine the transducer's electroacoustic parameters and acoustic output power using the self-reciprocity method, c) the criteria for checking the reciprocity of these transducers and the linear range of the focused field, and d) guiding information for the assessment of the overall measurement uncertainties for radiation conductance.
Committee |
EPL/87
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
This document, which is a Technical Specification, establishes the free-field convergent spherical wave self-reciprocity method for ultrasonic transducer calibration, establishes the measurement conditions and experimental procedure required to determine the transducer\'s electroacoustic parameters and acoustic output power using the self-reciprocity method, establishes the criteria for checking the reciprocity of these transducers and the linear range of the focused field, and provides guiding information for the assessment of the overall measurement uncertainties for radiation conductance. This document is applicable to: circular spherically curved concave focusing transducers without a centric hole working in the linear amplitude range, measurements in the frequency range 0,5 MHz to 15 MHz, and acoustic pressure amplitudes in the focused field within the linear amplitude range.
Standards | Relationship |
IEC TS 62903:2018 | Identical |
IEC 60565:2006 | Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61828:2001 | Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
IEC 62127-2:2007+AMD1:2013+AMD2:2017 CSV | Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz |
IEC 60866:1987 | Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz |
SAC GB/T 32522 : 2016 | ACOUSTICS - ELECTROACOUSTIC CHARACTERISTICS AND MEASUREMENTS OF SPHERICALLY FOCUSING ULTRASONIC TRANSDUCERS |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |