PD ISO/TR 10465-2:2007
Current
The latest, up-to-date edition.
Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) Comparison of static calculation methods
Hardcopy , PDF
English
31-10-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Symbols and abbreviated terms
4 Soil-load distribution
5 Soil load
5.1 General
5.2 Initial loadings
5.3 Long-term loading
6 Traffic loads
6.1 General
6.2 AWWA procedure
6.3 ATV procedure
7 Deflections
7.1 Resulting from vertical load
7.2 Aspects not covered by AWWA or ATV
7.3 Irregularities in the installation
8 Circumferential bending strain
8.1 AWWA procedure
8.2 ATV procedure
9 Buckling
9.1 General
9.2 AWWA procedure
9.3 ATV procedure
10 Internal-pressure effects
10.1 General
10.2 Pressure strain
10.3 Combined loading
10.4 Calculations based on stress
Bibliography
Describes a comparison of the ATV and AWWA methods for static calculations on underground GRP pipe installations.
Committee |
PRI/88
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This part of ISO10465 presents a comparison of the ATV and AWWA methods for static calculations on underground GRP pipe installations. It is intended that this comparison will encourage the use of both procedures for GRP pipes conforming to International Standards.
It is not the intent of this part of ISO10465 to cover all the details of the two methods. Some aspects are, of necessity, very complex, and for a full understanding the original documents need to be studied in detail. Rather, the intention is to give a general overview and comparison of the key elements so that the user can more easily understand and appreciate the differences between the two procedures and their similarities.
Standards | Relationship |
ISO/TR 10465-2:2007 | Identical |
AWWA M45 : 3 | FIBERGLASS PIPE DESIGN |
ISO/TS 10465-1:2007 | Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) — Part 1: Installation procedures |
ISO/TR 10465-3:2007 | Underground installation of flexible glass-reinforced pipes based on unsaturated polyester resin (GRP-UP) Part 3: Installation parameters and application limits |
DIN 1072:1985-12 | ROAD AND FOOT BRIDGES - DESIGN LOADS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.