PD ISO/TR 11583:2012
Current
The latest, up-to-date edition.
Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits
Hardcopy , PDF
English
31-05-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
5 Principle of the method of measurement
and computation
6 Venturi tubes
7 Orifice plates
8 Tracer techniques
9 Comparison method
10 Total mass flowrate known
11 Using a throttling calorimeter
12 Installation
13 Sampling
Annex A (informative) - Calculations
Bibliography
Provides the measurement of wet gas with differential pressure meters. Pertains to two-phase flows of gas and liquid in which the flowing fluid mixture consists of gas in the region of 95% volume fraction or more.
Committee |
CPI/30/2
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Technical Report describes the measurement of wet gas with differential pressure meters. It applies to two-phase flows of gas and liquid in which the flowing fluid mixture consists of gas in the region of 95%volume fraction or more (the exact limits on the mixture are defined in 6.4.3, 6.4.5, 7.5.3 and 7.5.5). This Technical Report is an extension of ISO5167. The ranges of gases and liquids from which the equations in this Technical Report were derived are given in 6.4.1 and 7.5.1. It is possible that the equations do not apply to liquids significantly different from those tested, particularly to highly viscous liquids.
Although the over-reading equations presented in this Technical Report apply for a wide range of gases and liquids at appropriate gas-liquid density ratios, evaluating gas flowrates depends on information in addition to that required in single-phase flow: under certain conditions, a measurement of the pressure loss is sufficient; tracers can be used to measure the liquid flow; the total mass flowrate may be known (this is more likely in a wet-steam flow than in a natural gas/liquid flow); in a wet-steam flow a throttling calorimeter can be used.
Wet-gas measurement using Venturi tubes or orifice plates is covered in this Technical Report.
This Technical Report is only applicable to wet gas flows with a single liquid and is not intended for the oil and gas industry.
Standards | Relationship |
ISO/TR 11583:2012 | Identical |
ISO/TR 15377:2007 | Measurement of fluid flow by means of pressure-differential devices Guidelines for the specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167 |
ISO 3171:1988 | Petroleum liquids — Automatic pipeline sampling |
ISO 10715:1997 | Natural gas — Sampling guidelines |
ISO 3170:2004 | Petroleum liquids — Manual sampling |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
GPA 2165 : 1995 | STANDARD FOR ANALYSIS OF NATURAL GAS LIQUID MIXTURES BY GAS CHROMATOGRAPHY |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ASME MFC 19G : 2008 | WET GAS FLOWMETERING GUIDELINE |
ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
IP 345 : 80(R1995) | DETERMINATION OF COMPOSITION OF ASSOCIATED NATURAL GAS - GAS CHROMATOGRAPHY METHOD |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |