PD ISO/TR 24578:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Hydrometry. Acoustic Doppler profiler. Method and application for measurement of flow in open channels
30-06-2012
16-03-2021
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principles of operation
5 Principles of methods of measurement
6 Site selection for the use of vertically mounted ADCPs
7 Computation of measurement
8 Uncertainty
Annex A (informative) - Velocity distribution theory and
the extrapolation of velocity profiles
Annex B (informative) - Determination of discharge
between banks and the area of measured
discharge
Annex C (informative) - Example of an equipment check
list
Annex D (informative) - Example of ADCP gauging field
sheets
Annex E (informative) - Beam alignment test
Bibliography
Describes the use of boat-mounted acoustic Doppler current profilers (ADCPs) for determining flow in open channels without ice cover.
| Committee |
CPI/113
|
| DocumentType |
Standard
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| ISO/TR 24578:2012 | Identical |
| ISO 748:2007 | Hydrometry — Measurement of liquid flow in open channels using current-meters or floats |
| ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
| ISO/TS 25377:2007 | Hydrometric uncertainty guidance (HUG) |
| ISO/TS 24154:2005 | Hydrometry — Measuring river velocity and discharge with acoustic Doppler profilers |
| ISO 772:1996 | Hydrometric determinations — Vocabulary and symbols |