Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 How the structure of this guide relates to
  ISO 5167:2003 (all parts)
5 Guidance on the use of ISO 5157:2003 (all parts)
  5.1 Guidance specific to the use of ISO 5167-1:2003
  5.2 Guidance specific to the use of ISO 5167-2:2003
  5.3 Guidance specific to the use of ISO 5167-3:2003
  5.4 Guidance specific to the use of ISO 5167-4:2003
6 Information of a general nature relevant to the
  application of ISO 5167:2003 (all parts)
  6.1 Secondary instrumentation
  6.2 Measurement of pressure and differential pressure
  6.3 Measurement of temperature
  6.4 Determination of density
  6.5 Electrical supply and electrical installations
Annex A (informative) - Principles of measurement and computation
Annex B (informative) - Computation of compressibility factor
                        for natural gases
Annex C (informative) - Orifice plate assembly
Bibliography

Provides guidance on the use of ISO 5167:2003 (all parts).

Committee
CPI/30/2
DevelopmentNote
Supersedes BS ISO TR 9464. (06/2008)
DocumentType
Standard
Pages
78
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

The objective of this Technical Report is to provide guidance on the use of ISO5167:2003 (all parts). ISO5167:2003 is an International Standard for flow measurement based on the differential pressure generated by a constriction introduced into a circular conduit (see ISO5167-1:2003, 5.1). It presents a set of rules and requirements based on theory and experimental work undertaken in the field of flow measurement.

For a more detailed description of the scope, reference should be made to ISO5167-1:2003, Clause1. Definitions and symbols applicable to this Technical Report are given in ISO5167-1:2003, Clauses3 and 4.

Neither ISO5167-1:2003 nor this Technical Report give detailed theoretical background, for which reference should be made to any general textbook on fluid flow.

With the application of the rules and requirements set out in ISO5167-1:2003, it is practicable to achieve flow measurement within an uncertainty of approximately 1%of the calculated flowrate. The constraints applicable to each of the primary devices described in ISO5167:2003 (parts 2 to 4) need to be given consideration before determining the most suitable type for a particular application. Parts 2 to 4 can also be used to form the basis for preliminary design of a metering system.

The information necessary for detailed design, manufacture and final check is specified in the clauses and paragraphs of ISO5167:2003 (parts 2 to 4).

Secondary instrumentation is not covered by ISO5167-1:2003, but Clause6 of this Technical Report makes normative reference to ISO2186.

Standards Relationship
ISO/TR 9464:2008 Identical

ISO 5167-3:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles
ISO 5168:2005 Measurement of fluid flow — Procedures for the evaluation of uncertainties
ISO/IEC Guide 98:1993 Guide to the expression of uncertainty in measurement (GUM)
ISO 5167-4:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes
ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates
ISO/TR 3313:1998 Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60751:2008 Industrial platinum resistance thermometers and platinum temperature sensors
ISO 2186:2007 Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements
ISO 4006:1991 Measurement of fluid flow in closed conduits — Vocabulary and symbols

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.