PD ISO/TS 5660-3:2012
Current
The latest, up-to-date edition.
Reaction-to-fire tests. Heat release, smoke production and mass loss rate Guidance on measurement
Hardcopy , PDF
English
30-06-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Capability and limitations of the cone calorimeter
4 Calibration of the cone calorimeter
5 Test specimen preparation and presentation
6 Selection of heat flux
7 Ignition protocols
8 Guidance on the testing of non-standard products
9 Composites and layered products
10 Liquids
11 The theory of oxygen consumption calorimetry
12 Start and end of test
13 Recommendations for presentation of data
Annex A (informative) - Predictive methods from
ISO 5660-1 data
Annex B (informative) - Effect of additives and fillers
Annex C (informative) - Measurements at low levels
of heat release
Bibliography
Observes the measurement limitations and applications of the cone calorimeter data as currently used for building products, and recommends ways in which some of these may be overcome for other types of products for other application areas.
Committee |
FSH/21/-/5
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Standards | Relationship |
ISO/TS 5660-3:2012 | Identical |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO/TR 9122-1:1989 | Toxicity testing of fire effluents Part 1: General |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
NFPA 264A : 1994 | STANDARD METHOD OF TEST FOR HEAT RELEASE RATES FOR UPHOLSTERED FURNITURE COMPONENTS OR COMPOSITES AND MATTRESSES USING AN OXYGEN CONSUMPTION CALOMETER |
ISO/TS 14934-1:2002 | Fire tests Calibration and use of radiometers and heat flux meters Part 1: General principles |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 29473:2010 | Fire tests — Uncertainty of measurements in fire tests |
ISO/TR 3814:1989 | Tests for measuring "reaction-to-fire" of building materials — Their development and application |
ISO 17554:2014 | Reaction to fire tests Mass loss measurement |
ISO 5660-4:2008 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 4: Measurement of heat release for determination of low levels of combustibility |
ASTM E 1474 : 2014 : REDLINE | Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter |
ISO/TS 14934-4:2007 | Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
ISO 554:1976 | Standard atmospheres for conditioning and/or testing — Specifications |
ISO/TR 14697:1997 | Fire tests — Guidance on the choice of substrates for building products |
ISO 13927:2015 | Plastics — Simple heat release test using a conical radiant heater and a thermopile detector |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
ISO 11907-4:1998 | Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 4: Dynamic decomposition method using a conical radiant heater |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.