
PREN 16416 : DRAFT 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

GEOSYNTHETIC CLAY BARRIERS - DETERMINATION OF WATER FLUX INDEX - FLEXIBLE WALL PERMEAMETER METHOD AT CONSTANT HEAD
01-09-2013
12-01-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Apparatus
5 Permeant water
6 Specimen sampling and preparation
7 Procedure
8 Calculation
9 Report
Annex A (informative) - Hydraulic conductivity
calculation
Annex B (informative) - Permittivity calculation
based on ASTM D 4491
Bibliography
Provides an index test method that covers laboratory measurement of water flux through saturated geosynthetic clay barrier (GBR-C) specimens using a flexible wall permeameter at constant head.
Committee |
TC 189
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
Standards | Relationship |
DIN EN 16416:2013-12 | Identical |
12/30259433 DC : 0 | Identical |
BS EN 13493:2013 | Geosynthetic barriers. Characteristics required for use in the construction of solid waste storage and disposal sites |
BS EN 13492:2013 | Geosynthetic barriers. Characteristics required for use in the construction of liquid waste disposal sites, transfer stations or secondary containment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.