• PREN 54-12 : DRAFT 2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM

    Available format(s): 

    Superseded date:  01-04-2015

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
      4.1 Compliance
      4.2 Individual alarm indication
      4.3 Connection of ancillary devices
      4.4 Manufacturer's adjustments
      4.5 On-site adjustment of response threshold value
      4.6 Protection against ingress of foreign bodies
      4.7 Monitoring of detachable detectors and connections
      4.8 Response to slowly developing fires
      4.9 Marking
      4.10 Documentation
      4.10 General
      4.11 Additional requirements for software controlled
           detectors
    5 Tests
      5.1 General
      5.2 Reproducibility
      5.3 Repeatability
      5.4 Tolerance to beam misalignment
      5.6 Rapid changes in attenuation
      5.7 Optical path length dependence
      5.8 Fire sensitivity
      5.9 Stray light
      5.10 Dry heat (operational)
      5.11 Cold (operational)
      5.12 Damp heat, steady state (operational)
      5.13 Damp heat, steady state (endurance)
      5.14 Vibration (endurance)
      5.15 Electromagnetic compatibility (EMC), immunity tests
           (operational)
      5.16 Sulphur dioxide SO[2] corrosion (endurance)
      5.17 Impact (operational)
    Annex A (normative) - Bench for response threshold value
            measurements
      A.1 Technical characteristics of the attenuators
      A.2 Measuring bench
    Annex B (normative) - Fire test room
    Annex C (normative) - Smouldering pyrolysis wood fire (TF2)
      C.1 Fuel
      C.2 Hotplate
      C.3 Arrangement
      C.4 Heating rate
      C.5 End of test condition
      C.6 Test validity criteria
    Annex D (normative) - Glowing smouldering cotton fire (TF3)
      D.1 Fuel
      D.2 Arrangement
      D.3 Ignition
      D.4 End of test condition
      D.5 Test validity criteria
    Annex E (normative) - Flaming plastics (polyurethane) fire (TF4)
      E.1 Fuel
      E.2 Arrangement
      E.3 Ignition
      E.4 End of test condition
      E.5 Test validity criteria
    Annex F (normative) - Flaming liquid (n-heptane) fire (TF5)
      F.1 Fuel
      F.2 Arrangement
      F.3 Ignition
      F.4 End of test condition
      F.5 Test validity criteria
    Annex G (normative) - Apparatus for stray light
      G.1 Installation
      G.2 The light source
    Annex H (informative) - Information concerning the requirements
            for the response to slowly developing fires
    Annex ZA (informative) - Clauses of this European Standard
             addressing essential requirements or other
             provisions of EU Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements, test methods and performance criteria for line smoke detectors utilising the attenuation and/or changes in attenuation of an optical beam, for use in fire detection systems installed in buildings.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee TC 72
    Document Type Draft
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    National Adoptions - (Show below) - (Hide below)

    Equivalent Standard(s) Relationship
    09/30170243 DC : 0 Identical

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    ISO 9001:2015 Quality management systems — Requirements
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective