SAE AIR38B
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Guide for the Design of Threaded Screw or Stud Type Electrical Equipment Terminations
Hardcopy , PDF
English
16-10-2015
09-06-2023
1. SCOPE
2. REFERENCES
3. GENERAL
4. SCREW AND STUD SIZE SELECTION
5. TERMINAL CONTACT AREA DESIGN
6. INSULATOR DESIGN
7. FASTENER HARDWARE
8. HARDWARE ARRANGEMENTS
9. SPECIAL TOOLS
10. NOTES
Sets up design recommendations that will provide a basis for safe and reliable connections to threaded screw- or stud-type electrical equipment terminations.
| DocumentType |
Standard
|
| Pages |
19
|
| PublisherName |
SAE International
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
To establish design recommendations that will provide a basis for safe and reliable connections to threaded screw- or stud-type electrical equipment terminations. These recommendations are directed primarily, but not solely, to the aerospace and ground support equipment industries.Since individual design criteria may alter the details as outlined, it is therefore important that this Aerospace Information Report (AIR) not be considered mandatory, but be used only as a design guide.
| SAE AS7928/7A | TERMINAL LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER, TERMINAL LUG, CRIMP STYLE, COPPER, UNINSULATED, RING TONGUE TYPE I, CLASS 1 FOR 175 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS7928/10A | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, SPLICE, ELECTRIC, TIN WHISKER (PERMANENT, TYPE II, CLASS 1) FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS7928/6B | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, SPLICE, ELECTRIC (PERMANENT, TYPE II, CLASS 1) FOR 150 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS 7928/5 : 2016 | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, SPLICE, ELECTRIC (PERMANENT, TYPE 2, CLASS 1) FOR 105 DEGREES C TOTAL CONDUCTOR TEMPERATURE |
| FF-N-836 Revision E:1994 | Nut: Square, Hexagon, Cap, Slotted, Castle, Knurled, Welding and Single Ball Seat |
| MIL-HDBK-454 Revision B:2007 | General Guidelines for Electronic Equipment |
| MIL-STD-889 Revision C:2016 | Galvanic Compatibility of Electrically Conductive Materials |
| SAE AS7928/5B | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, SPLICE, ELECTRIC (PERMANENT, TYPE II, CLASS 1) FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS7928/11C | TERMINAL, LUG, CRIMP STYLE, COPPER, UNINSULATED, RING TONGUE, TIN WHISKER RESISTANT, TYPE I, CLASS I, FOR 175 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS 7928/10 : 2016 | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, SPLICE, ELECTRIC, TIN WHISKER (PERMANENT, TYPE 2, CLASS 1) FOR 105 DEGREES C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS21004B | TERMINAL, LUG, UNINSULATED, RECTANGULAR TONGUE, CRIMP STYLE, COPPER, TYPE I, CLASS 1 FOR 175 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS20659E | TERMINAL, LUG, CRIMP STYLE, COPPER, UNINSULATED, RING TONGUE, TYPE I, CLASS 1, FOR 175 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS50151C | Connectors, Electrical, Circular Threaded, AN Type, General Specification For |
| SAE AS70991B | Terminals: Lug and Splice, Crimp Style, Aluminum, For Aluminum Aircraft Wire |
| SAE AS7928B | Terminals, Lug: Splices, Conductor: Crimp Style, Copper, General Specification For |
| SAE AS7928/1D | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER TERMINAL, LUG, CRIMP STYLE, COPPER, INSULATED, RING TONGUE, FOR THIN WALL WIRE, TYPE II CLASS 1 FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS7928/13A | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER TERMINAL, LUG, INSULATED, TIN WHISKER RESISTANT, RING TONGUE, BELL-MOUTHED, TYPE II, CLASS 1 (FOR 105°C TOTAL CONDUCTOR TEMPERATURE) |
| SAE AS7928/2C | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER, INSULATED, RECTANGULAR TONGUE, FOR THIN WALL WIRE, TYPE II, CLASS 1 FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| SAE AS7928/12D | TERMINAL, LUG, CRIMP STYLE, COPPER, INSULATED, RING TONGUE, BELL-MOUTHED, TIN WHISKER RESISTANT, TYPE II, CLASS 1, (FOR 105 °C TOTAL CONDUCTOR TEMPERATURE) |
| MIL-STD-7179 Revision A:2009 | Finishes, Coatings, and Sealants, for the Protection of Aerospace Weapons Systems and Support Equipment |
| MIL-STD-108 Revision E:1966 | Definitions of and Basic Requirements for Enclosures for Electric and Electronic Equipment |
| SAE AS27212A | TERMINAL BOARD ASSEMBLY, MOLDED-IN-STUD, ELECTRIC |
| SAE AS50881F | Wiring Aerospace Vehicle |
| MIL-PRF-6106 Revision P:2014 | Relays, Electromagnetic General Specification for |
| SAE AS7928/8A | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER TERMINAL, LUG, CRIMP STYLE, COPPER, INSULATED, RING TONGUE, FOR THIN WALL WIRE, TIN WHISKER RESISTANT, TYPE II CLASS 1 FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| FF-S-92 Revision C:2014 | Screw, Machine, Slotted, Cross-Recessed or Hexagon Head |
| A-A-59126 Revision B:2012 | Terminals, Feedthru (Insulated) and Terminals, Stud (Insulated and Noninsulated) |
| SAE AS7928/9A | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER, INSULATED, RECTANGULAR TONGUE, TIN WHISKER RESISTANT FOR THIN WALL WIRE, TYPE II, CLASS 1 FOR 105 °C TOTAL CONDUCTOR TEMPERATURE |
| MIL-STD-1285 Revision D:2004 | Marking of Electrical and Electronic Parts |
| FED-STD-H28 Revision A:1994 | Screw-Thread Standards for Federal Services |
| MIL-HDBK-1277 Base Document:1998 | Splices, Chips, Terminals, Terminal Boards, Binding Posts, Electrical |
| SAE AIR1263 | TIN PLATED SOLDERLESS TERMINAL LUGS AND SPLICES ON NICKEL COATED HIGH TEMPERATURE WIRE |
| MS25435 Revision A:1964 | Terminal, Lug, Crimp Style, for Aluminum Aircraft Wire Class 1 (S/S by SAE-AS25435) |
| SAE AS7928/4B | TERMINALS, LUG AND SPLICES, CONDUCTOR, CRIMP STYLE, COPPER TERMINAL, LUG, INSULATED, RING TONGUE, BELL-MOUTHED, TYPE II, CLASS 1 (FOR 150 °C TOTAL CONDUCTOR TEMPERATURE) |
| FF-S-85 Revision D:2005 | Screw, Cap, Slotted and Hexagon Head |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.