SAE ARP1179A
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AIRCRAFT GAS TURBINE ENGINE EXHAUST SMOKE MEASUREMENT
Hardcopy , PDF
19-04-1991
English
04-05-1970
DocumentType |
Standard
|
Pages |
10
|
PublisherName |
SAE International
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Aerospace Recommended Practice (ARP) standardizes test equipment and procedures for the measurement of smoke emission from aircraft gas turbine engines. The procedures included are for determining and reporting the amount of smoke emission. Tests have indicated that the practically achieveable precision of the smoke number is within ±3 when the system is properly used as outlined herein. This procedure is not intended for in-flight testing, nor does it apply to afterburning engines.This ARP is divided into the following sections:2Definitions and Terminology3Equipment4Test Procedures5Information and Data to be Recorded6Data Reduction and Analysis7Presentation of Results8Comments
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.