• Shopping Cart
    There are no items in your cart

SAE ARP1179B

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

AIRCRAFT GAS TURBINE ENGINE EXHAUST SMOKE MEASUREMENT

Available format(s)

Hardcopy , PDF

Superseded date

01-10-1997

Superseded by

SAE ARP1179C

Language(s)

English

Published date

19-04-1991

€105.53
Excluding VAT

DocumentType
Standard
Pages
13
PublisherName
SAE International
Status
Superseded
SupersededBy
Supersedes

This Aerospace Recommended Practice (ARP) standardizes test equipment and procedures for the measurement of smoke emission from aircraft gas turbine engines. The procedures included are for determining and reporting the amount of smoke emission. Tests have indicated that the practically achieveable precision of the smoke number is within ±3 when the system is properly used as outlined herein. This procedure is not intended for in-flight testing, nor does it apply to engines operating in the afterburning mode.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.