• Shopping Cart
    There are no items in your cart

SAE AS58091A

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Circuit Breakers, Trip-Free, Aircraft General Specification For

Published date

31-05-2012

Superseded date

23-10-2023

Superseded by

SAE AS58091B

Sorry this product is not available in your region.

1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. QUALITY ASSURANCE PROVISIONS
5. PREPARATION FOR DELIVERY
6. NOTES
APPENDIX A - CIRCUIT BREAKER, FIRST STEP SELECTION GUIDE

Specifies the general requirements of one-, two-, and three-phase (often referred to as poles) trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704.

DevelopmentNote
Supersedes MIL C 5809 (G). (04/2005)
DocumentType
Standard
PublisherName
SAE International
Status
Superseded
SupersededBy
Supersedes

The primary function of this specification is to cover the general requirements of one-, two-, and three-phase (often referred to as poles) trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements of one-, two- and three-phase circuit breakers for use in primary vehicles, other than aircraft, when mounted directly to the structure.

MIL-PRF-24236 Revision D:2006 Switches, Thermostatic, (Metallic and Bimetallic), General Specification for
MIL-PRF-83383-4 Revision G:2017 Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Triple Pole, Auxiliary Contacts (5 to 100 Amperes)
MIL-PRF-83383-11 Base Document:2007 Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts, Internal Wiring Connection for Multiple Line Protection (5 to 100 Amperes) (No S/S Document)
MIL-PRF-83383-10 Base Document:2007 Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Internal Wiring Connection for Multiple Line Protection (5 TO 100 Amperes) (No S/S Document)
SAE AS26574A CIRCUIT BREAKER - TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMP, TYPE I
MIL-PRF-22885 Revision J:2016 Switches, Push Button, Illuminated General Specification for
MIL-DTL-28827 Revision C:2011 Switches, Thermostatic, (Volatile Liquid), Hermetically Sealed, General Specification for
MIL-PRF-8805 Revision G:2016 Switches and Switch Assemblies, Sensitive, Snap Action (Basic, Limit, Push Button and Toggle Switches), General Specification for
SAE ARP4404C Aircraft Electrical Installations
MIL-PRF-83383-2 Revision G:2016 Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts (5 to 100 Amperes)
MIL-PRF-83383-1 Revision G:2016 Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, (5 to 100 Amperes)
MIL-DTL-8834 Revision K:2016 Switches, Toggle, Positive Break, General Specification for

MIL-STD-704 Revision F:2004 Aircraft Electric Power Characteristics
SAE AS21984B CIRCUIT BREAKER-AIRCRAFT, TRIP-FREE PUSH-PULL, 3-PHASE, 5 THRU 60 AMP., TYPE I
SAE AS24510A CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 5 THRU 15 AMP, TYPE I
SAE AS22073B CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMP, TYPE I
MIL-HDBK-454 Revision B:2007 General Guidelines for Electronic Equipment
MIL-STD-889 Revision C:2016 Galvanic Compatibility of Electrically Conductive Materials
SAE AS14153C CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL 3 PHASE, 1 THROUGH 35 AMP, TYPE 1
SAE AS22759C Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy
ANSI/NCSL Z540 1 : 94(R2002) CALIBRATION - CALIBRATION LABORATORIES AND MEASURING AND TEST EQUIPMENT - GENERAL REQUIREMENTS
SAE AS25361B CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 50 THRU 100 AMP, TYPE I
SAE AS25337A CIRCUIT BREAKER, AIRCRAFT TRIP-FREE TOGGLE, 5-50 AMP
SAE AS24509A CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, TOGGLE, 5 THRU 15 AMP, TYPE I
SAE AS7928B Terminals, Lug: Splices, Conductor: Crimp Style, Copper, General Specification For
MIL-I-24768-17 Base Document:1992 Insulation, Plastic, Laminated, Thermosetting, Glass-Cloth, Silicone-Resin (GSG)
SAE AS50861A Wire, Electric, Polyvinyl Chloride Insulated, Copper or Copper Alloy
SAE AS81044A Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy
SAE AS33201A CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMPS, TYPE I −55 THRU +121 °C
SAE AS22074A CIRCUIT BREAKER, RECYCLING, TRIP-FREE, PUSH-PULL, 1/2 THRU 5 AMPERE, TYPE I
SAE AS25244B CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, 5 THRU 50 AMP, TYPE I
MIL-STD-202 Revision H:2015 Electronic and Electrical Component Parts
MIL-STD-1285 Revision D:2004 Marking of Electrical and Electronic Parts
MIL-I-24768 Base Document:1992 Insulation, Plastics, Laminated, Thermosetting; General Specification for
MIL-STD-104 Revision C:1986 Limit for Electrical Insulation Color
ASME Y14.100 : 2017 ENGINEERING DRAWING PRACTICES - ENGINEERING DRAWING AND RELATED DOCUMENTATION PRACTICES
SD 6 : 20140201 PROVISIONS GOVERNING QUALIFICATION: QUALIFIED PRODUCTS LIST AND QUALIFIED MANUFACTURERS LISTS
MIL-E-17555 Revision H:1984 Electronic and Electrical Equipment, Accessories, and Provisioned Items (Repair Parts): Packaging of (No S/S Document)
MIL-S-7742 Revision D:1991 Screw Threads, Standard, Optimum Selected Series: General Specification for

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Sorry this product is not available in your region.