SAE AS58091A
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Circuit Breakers, Trip-Free, Aircraft General Specification For
31-05-2012
23-10-2023
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. QUALITY ASSURANCE PROVISIONS
5. PREPARATION FOR DELIVERY
6. NOTES
APPENDIX A - CIRCUIT BREAKER, FIRST STEP SELECTION GUIDE
Specifies the general requirements of one-, two-, and three-phase (often referred to as poles) trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704.
| DevelopmentNote |
Supersedes MIL C 5809 (G). (04/2005)
|
| DocumentType |
Standard
|
| PublisherName |
SAE International
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
The primary function of this specification is to cover the general requirements of one-, two-, and three-phase (often referred to as poles) trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements of one-, two- and three-phase circuit breakers for use in primary vehicles, other than aircraft, when mounted directly to the structure.
| MIL-PRF-24236 Revision D:2006 | Switches, Thermostatic, (Metallic and Bimetallic), General Specification for |
| MIL-PRF-83383-4 Revision G:2017 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Triple Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-PRF-83383-11 Base Document:2007 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts, Internal Wiring Connection for Multiple Line Protection (5 to 100 Amperes) (No S/S Document) |
| MIL-PRF-83383-10 Base Document:2007 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Internal Wiring Connection for Multiple Line Protection (5 TO 100 Amperes) (No S/S Document) |
| SAE AS26574A | CIRCUIT BREAKER - TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMP, TYPE I |
| MIL-PRF-22885 Revision J:2016 | Switches, Push Button, Illuminated General Specification for |
| MIL-DTL-28827 Revision C:2011 | Switches, Thermostatic, (Volatile Liquid), Hermetically Sealed, General Specification for |
| MIL-PRF-8805 Revision G:2016 | Switches and Switch Assemblies, Sensitive, Snap Action (Basic, Limit, Push Button and Toggle Switches), General Specification for |
| SAE ARP4404C | Aircraft Electrical Installations |
| MIL-PRF-83383-2 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-PRF-83383-1 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, (5 to 100 Amperes) |
| MIL-DTL-8834 Revision K:2016 | Switches, Toggle, Positive Break, General Specification for |
| MIL-STD-704 Revision F:2004 | Aircraft Electric Power Characteristics |
| SAE AS21984B | CIRCUIT BREAKER-AIRCRAFT, TRIP-FREE PUSH-PULL, 3-PHASE, 5 THRU 60 AMP., TYPE I |
| SAE AS24510A | CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 5 THRU 15 AMP, TYPE I |
| SAE AS22073B | CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMP, TYPE I |
| MIL-HDBK-454 Revision B:2007 | General Guidelines for Electronic Equipment |
| MIL-STD-889 Revision C:2016 | Galvanic Compatibility of Electrically Conductive Materials |
| SAE AS14153C | CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL 3 PHASE, 1 THROUGH 35 AMP, TYPE 1 |
| SAE AS22759C | Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy |
| ANSI/NCSL Z540 1 : 94(R2002) | CALIBRATION - CALIBRATION LABORATORIES AND MEASURING AND TEST EQUIPMENT - GENERAL REQUIREMENTS |
| SAE AS25361B | CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 50 THRU 100 AMP, TYPE I |
| SAE AS25337A | CIRCUIT BREAKER, AIRCRAFT TRIP-FREE TOGGLE, 5-50 AMP |
| SAE AS24509A | CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, TOGGLE, 5 THRU 15 AMP, TYPE I |
| SAE AS7928B | Terminals, Lug: Splices, Conductor: Crimp Style, Copper, General Specification For |
| MIL-I-24768-17 Base Document:1992 | Insulation, Plastic, Laminated, Thermosetting, Glass-Cloth, Silicone-Resin (GSG) |
| SAE AS50861A | Wire, Electric, Polyvinyl Chloride Insulated, Copper or Copper Alloy |
| SAE AS81044A | Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy |
| SAE AS33201A | CIRCUIT BREAKER - AIRCRAFT, TRIP-FREE, PUSH-PULL, 1/2 THRU 20 AMPS, TYPE I −55 THRU +121 °C |
| SAE AS22074A | CIRCUIT BREAKER, RECYCLING, TRIP-FREE, PUSH-PULL, 1/2 THRU 5 AMPERE, TYPE I |
| SAE AS25244B | CIRCUIT BREAKER, TRIP-FREE, PUSH-PULL, 5 THRU 50 AMP, TYPE I |
| MIL-STD-202 Revision H:2015 | Electronic and Electrical Component Parts |
| MIL-STD-1285 Revision D:2004 | Marking of Electrical and Electronic Parts |
| MIL-I-24768 Base Document:1992 | Insulation, Plastics, Laminated, Thermosetting; General Specification for |
| MIL-STD-104 Revision C:1986 | Limit for Electrical Insulation Color |
| ASME Y14.100 : 2017 | ENGINEERING DRAWING PRACTICES - ENGINEERING DRAWING AND RELATED DOCUMENTATION PRACTICES |
| SD 6 : 20140201 | PROVISIONS GOVERNING QUALIFICATION: QUALIFIED PRODUCTS LIST AND QUALIFIED MANUFACTURERS LISTS |
| MIL-E-17555 Revision H:1984 | Electronic and Electrical Equipment, Accessories, and Provisioned Items (Repair Parts): Packaging of (No S/S Document) |
| MIL-S-7742 Revision D:1991 | Screw Threads, Standard, Optimum Selected Series: General Specification for |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.