SAE J2297_201301
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Ultraviolet Leak Detection: Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Conditioning Systems
12-06-2013
14-01-2013
1. SCOPE
2. REFERENCES
3. SPECIFICATION AND GENERAL DESCRIPTION
4. USE INSTRUCTIONS
5. ASSOCIATED EQUIPMENT
6. TESTING OF FLUORESCENT LEAK DETECTION DYES
7. STABILITY TESTING
8. FLUORESCENCE TESTING
9. NONMETALLIC MATERIALS COMPATIBILITY TESTING
10. WEAR TESTING
11. VISCOSITY EFFECT TESTING
12. COMPLIANCE
13. NOTES
APPENDIX A - TEST VERIFICATION TABLE A TO CERTIFY
COMPLIANCE ACCORDING TO SAE J2911
This SAE Standard applies to dyes intended to be introduced into a mobile air-conditioning system refrigerant circuit for the purpose of allowing the application of ultraviolet leak detection.
DocumentType |
Standard
|
PublisherName |
SAE International
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This SAE Standard applies to dyes intended to be introduced into a mobile air-conditioning system refrigerant circuit for the purpose of allowing the application of ultraviolet leak detection. In order to label any product(s) they shall meet SAE J2297, and the certification process as described in SAE J2911 must be followed and the documentation described in the appendix shall be submitted to SAE.
SAE J1628_201407 | Technician Procedures for Refrigerant Leak Detection in Service of Mobile Air Conditioning Systems |
SAE J2776_201301 | Refrigerant Purity and Container Requirements for New HFC-134a 1,1,1,2 - Tetrafluoroethane Refrigerant Used in Mobile Air-Conditioning Systems |
SAE J2844_201301 | R-1234yf (HFO-1234yf) New Refrigerant Purity and Container Requirements for Use in Mobile Air-Conditioning Systems |
ASHRAE 97 : 2007(RA2017) | Sealed Glass Tube Method to Test the Chemical Stability of Materials for Use within Refrigerant Systems<br> |
SAE J2298_201108 | Ultraviolet Leak Detection: Procedure for Use of Refrigerant Leak Detection Dyes for Service of Mobile Air-Conditioning Systems |
SAE J2299_201201 | Ultraviolet Leak Detection: Performance Requirements for Fluorescent Refrigerant Leak Detection Dye Injection Equipment for Aftermarket Service of Mobile Air-Conditioning Systems |
SAE J2911_201612 | Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.