1.0 SCOPE
2.0 REFERENCE DOCUMENTS
3.0 GENERAL REQUIREMENTS
4.0 TEST PROCEDURES AND ACCEPTANCE CRITERIA
5.0 VALIDATION REQUIREMENTS FOR WELDED WIRE/CABLE
    TERMINATION
APPENDIX A - DEFINITIONS
APPENDIX B - ABBREVIATIONS
APPENDIX C - WELD DEVELOPMENT AND WELD GEOMETRY
             REFERENCE INFORMATION
APPENDIX D - METHOD TO VALIDATE A RANGE OF PROCESS
             SETTINGS
APPENDIX E - QUALITY CONTROL TECHNIQUES
APPENDIX F - REVISION RECORD

Describes test methods and performance criteria for evaluating ultrasonically welded wire-to-terminal metallurgical bonds.

DocumentType
Standard
PublisherName
SAE International
Status
Superseded
SupersededBy

IMPORTANT NOTICE: In any intended vehicle application, if the products covered by this specification are, or may be, subjected to conditions beyond those described in this document, they must pass special tests simulating the actual conditions to be encountered before they can be considered acceptable for actual vehicle application. Products certified by their supplier as having passed specific applicable portions of this specification are not to be used in applications where conditions may exceed those for which the product has been satisfactorily tested.The Authorized Person is the final authority as to what tests are to be performed on his or her parts and for what purpose these tests are required. He or she is also the final authority for resolving any questions related to testing to this specification and to authorizing any deviations to the equipment or procedures contained in this specification. Any such deviation must be documented and included in the final test report.1This specification defines basic test methods and requirements for ultrasonically welded cable termination type connections. These procedures are applicable to the ultrasonically welded cable attachment method to buss, terminal, or device connections including welded eyelet or battery terminations.2The wiring supplier has the primary responsibility for testing and selection of weld tooling and equipment.Specific terminal designs may require specialized ultrasonic weld tooling and equipment. The component supplier is responsible to provide the component processor or wire harness supplier information based on the weld tooling and equipment used in the terminal DV and PV testing process.Traceability to the tooling and equipment used to prepare the samples under test must be documented in the test report. Obtaining approval from the customer with appropriate test data showing that the welded termination will function as defined by this specification lies with the wiring harness supplier.3New or revised ultrasonically welded terminations shall be tested to the requirements of this specification.4Deviations from the requirements of this specification must be approved by the customer engineering department.5Procedures included within this specification are intended to cover performance testing and development of welded cable terminations that are part of the electrical connection systems used in road vehicle applications at ambient temperatures of 125°C maximum. The OEM customer must approve use of these test procedures for use at temperatures beyond this limit.6Welded terminations using crimped insulation wings for strain relief shall meet the insulation crimped grip requirements of SAE/USCAR 21.NOTE: This specification was developed with clean, bare, uncoated, stranded automotive copper wire. Welded terminations using compressed, compacted, or solid core construction or other core materials (clad, steel core, etc) need to be reviewed to determine that this specification is applicable to evaluate those terminations. Coating, lubricants, or contamination in the bond area of wires or components can affect the mechanical and electrical performance of ultrasonically welded cable terminations. For the purpose this specification the words: cable and wire shall be used interchangeably

SAE USCAR2-6 Performance Specification for Automotive Electrical Connector Systems
ISO 6722-2:2013 Road vehicles — 60 V and 600 V single-core cables — Part 2: Dimensions, test methods and requirements for aluminium conductor cables
SAE USCAR21-3 PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS
SAE J1128_201512 Low Voltage Primary Cable
ISO 6722-1:2011 Road vehicles — 60 V and 600 V single-core cables — Part 1: Dimensions, test methods and requirements for copper conductor cables
SAE J1127_201512 Low Voltage Battery Cable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.