SN EN 50167 : 1994
Current
The latest, up-to-date edition.
SECTIONAL SPECIFICATION FOR HORIZONTAL FLOOR WIRING CABLES WITH A COMMON OVERALL SCREEN FOR USE IN DIGITAL COMMUNICATION
12-01-2013
1 Guide to use
1.1 Scope
1.2 Introduction
1.3 Installation considerations
1.4 Object
2. Definitions and requirements
2.1 General
2.2 Reference publications
2.3 Definitions
2.4 Materials and cable construction
2.4.1 General
2.4.2 Cable construction
2.4.3 Conductor
2.4.4 Insulation
2.4.5 Cable element
2.4.6 Screening of the cable element
2.4.7 Colour code of insulation
2.4.8 Cable make-up
2.4.9 Screening of the cable core
2.4.10 Sheath
2.4.11 Colour of sheath
2.4.12 Identification
2.4.13 Finished cable
2.4.14 Cable overall diameter
3 Characteristics and requirements
3.1 General
3.2 Electrical tests
3.2.1 Conductor resistance
3.2.2 Resistance unbalance
3.2.3 Dielectric strength
3.2.4 Insulation resistance
3.2.5 Mutual capacitance
3.2.6 Capacitance unbalance
3.2.7 Transfer impedance
3.3 Transmission characteristics
3.3.1 Velocity of propagation
3.3.2 Attenuation
3.3.3 Unbalance attenuation
3.3.4 Near-end crosstalk
3.3.5 Far-end crosstalk
3.3.6 Characteristics impedance
3.3.7 Structural Return Loss (SRL)
3.3.8 Longitudinal to Differential Conversion
Loss (LCL)
3.4 Mechanical and dimension characteristics and
requirements
3.4.1 Dimensional requirements
3.4.2 Elongation at break of conductors
3.4.3 Elongation and tensile strength at break of
the insulation
3.4.4 Elongation and tensile strength at break of sheath
3.4.5 Crushing of the cable
3.4.6 Impact test on the cable
3.4.7 Repeated bending of the cable
3.4.8 Tensile performance of the cable
3.5 Environmental characteristics
3.5.1 Shrinkage of insulation
3.5.2 Wrapping of insulation after thermal ageing
3.5.3 Bending of insulation at low temperature
3.5.4 Elongation and tensile strength at break of the
sheath after ageing
3.5.5 Sheath pressure test at high temperature
3.5.6 Cold bend of the cable
3.5.7 Heat shock
3.5.8 Flame propagation characteristics of single cable
3.5.9 Flame propagation characteristics of bunched
cables
3.5.10 Acid gas evolution
3.5.11 Smoke generation
3.5.12 Toxic gas emission
4 Quality assessment procedures
Annex A (informative) Attenuation NEXT and ACR
Covers individually screened pair(s) or quad(s) in cables for horizontal floor wiring. Deals with cables that are meant to operate with voltages and currents normally adopted for communication systems.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Current
|
Standards | Relationship |
DIN EN 50167 : 1995 | Identical |
I.S. EN 50167:1995 | Identical |
UNE-EN 50167:1996 | Identical |
BS EN 50167:1996 | Identical |
EN 50167:1994 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.