SN EN 50379-2 : 2012
Current
The latest, up-to-date edition.
SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT
12-01-2013
Introduction
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 Test methods and performance requirements
5.1 General requirements for tests
5.1.1 Samples and sequence of tests
5.1.2 Preparation of samples
5.1.3 Test facility
5.2 Normal conditions for tests
5.3 Mechanical tests
5.3.1 Degree of protection
5.3.2 Impact strength
5.3.3 Vibration
5.3.4 Drop
5.3.5 Flow indicator (if fitted)
5.3.6 Dust filter and water trap
5.4 Electrical and software tests
5.4.1 EMC
5.4.2 Supply voltage variations (not applicable to
battery powered apparatus)
5.4.3 Battery fault condition (applicable only to
battery powered apparatus)
5.4.4 Battery reversal (applicable only to battery
powered apparatus)
5.4.5 Software and digital techniques
5.5 Tests with test gases
5.5.1 General
5.5.2 Unpowered storage
5.5.3 Initial performance
5.5.4 Response time
5.5.5 Cold start
5.5.6 Zero reading
5.6 Tests with real flue gases
5.6.1 General
5.6.2 Measurement uncertainty
5.6.3 Low temperature (applicable only to apparatus
designed for outdoor use)
5.6.4 Stability under practical conditions
5.6.5 Test of filter capacity
5.6.6 Final test with cylinder gases
5.6.7 Sensor replacement (where applicable)
5.7 Calculated values
5.7.1 General
5.7.2 Calculation of CO[2] gas volume ratio from
O[2] measurement
5.7.3 CO/CO[2] ratio
5.8 Temperature
5.8.1 Temperature measurement (flue gas)
5.8.2 Flue gas temperature response time
5.8.3 Temperature measurement (inlet air)
5.8.4 Inlet air temperature response time
5.8.5 Cold start
5.8.6 Thermocouple compensation
5.8.7 High temperature
5.9 Pressure
5.9.1 Pressure measurement (draught)
5.9.2 Pressure measurement (differential)
Annex A (informative) A-deviations
Specifies the performance requirements of portable spot reading apparatus designed to give a measurement of specific combustion flue gas parameters such as concentration of gaseous compounds, temperature and/or pressure to be used for testing the compliance with national regulations for the above mentioned appliances.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Current
|
Standards | Relationship |
NF EN 50379-2 : 2012 | Identical |
EN 50379-2:2012 | Identical |
BS EN 50379-2:2012 | Identical |
UNE-EN 50379-2:2013 | Identical |
I.S. EN 50379-2:2012 | Identical |
DIN EN 50379-2 : 2013 | Identical |
NBN EN 50379-2 : 2012 | Identical |
NEN EN 50379-2 : 2012 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.