SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS
15-01-2016
12-01-2013
Committees responsible
National foreword
Foreword
Section 1: General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
Section 2: Quality requirements and tests
2.1 Overvoltage protector
2.1.1 Protective spark gap
2.1.1.1 Purpose
2.1.1.2 Classification
2.1.1.3 Tests
2.1.2 Non-linear resistor (varistor)
2.1.2.1 Purpose
2.1.2.2 Classification
2.1.2.3 Tests
2.2 By-pass circuit-breaker
2.2.1 Purpose
2.2.2 Classification
2.2.3 Tests
2.3 Disconnector
2.3.1 Purpose
2.3.1.1 By-pass disconnector
2.3.1.2 Series disconnector
2.3.2 Classification
2.3.3 Tests
2.4 Current-limiting damping equipment
2.4.1 Purpose
2.4.2 Classification
2.4.3 Tests
2.5 Discharge reactor
2.5.1 Purpose
2.5.2 Classification
2.5.3 Tests
2.6 Voltage transformer
2.6.1 Purpose
2.6.2 Classification
2.6.3 Tests
2.7 Current transformer
2.7.1 Purpose
2.7.2 Classification
2.7.3 Tests
2.8 Signal column
2.8.1 Purpose
2.8.2 Classification
2.8.3 Tests
2.9 Relay protection, control equipment and
platform to ground communication equipment
2.9.1 Purpose
2.9.2 Classification
2.9.3 Tests
Section 3: Guide
3.1 General
3.2 Specification data for series capacitors
3.3 Protective spark gap
3.4 Non-linear resistor (varistor)
3.5 By-pass circuit-breaker
3.6 Disconnectors
3.7 Current-limiting damping equipment
3.8 Discharge reactor
3.9 Voltage transformer
3.10 Current transformer
3.11 Relay protection, control equipment and
platform to ground communication
3.12 Precommissioning tests
3.13 Commissioning tests
Annexes
A Bibliography
ZA (normative) Other international publications
quoted in this standard with the references of
the relevant European publications
Covers protective equipment for series capacitor banks, with a size larger than 10 Mvar per phase. Coverage includes: overvoltage protector, by-pass circuit-breaker, discharge reactor, voltage transformer, current transformer, and current-limiting damping equipment. Also gives definitions.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NF EN 60143-2 : 2013 | Identical |
UNE-EN 60143-2:1998 | Identical |
EN 60143-2:2013 | Identical |
DIN EN 60143-2 : 2014-01 | Identical |
NBN EN 60143-2 : 2013 | Identical |
I.S. EN 60143-2:2013 | Identical |
IEC 60143-2:2012 | Identical |
BS EN 60143-2:2013 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.