• There are no items in your cart

SN EN 60921 : 2004 AMD 1 2006

Current

Current

The latest, up-to-date edition.

BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS

Published date

12-01-2013

Sorry this product is not available in your region.

INTRODUCTION
1 Scope
2 Normative References
3 Terms and definitions
4 General notes on tests
5 Marking
6 Voltage at terminations of lamp or starter (if any)
   6.1 For lamps operated with a starter
   6.2 For lamps operated without a starter
   6.3 For lamps operated without a starter (North
       American practice)
   6.4 Maximum (r.m.s.) voltage across starter terminals
       with lamp operating
   6.5 For lamps with integral means of starting
7 Pre-heating conditions
   7.1 For lamps operated with (integral) starter
   7.2 For lamps operated without starter
   7.3 For lamps operated without starter (North American
       practice)
8 Lamp power and current
   8.1 For lamps operated with (integral) starter
   8.2 For lamps operated without starter
9 Circuit power-factor
10 Supply current
11 Maximum current in any lead to a cathode
12 Current waveform
13 Magnetic screening
14 Impedance at audio-frequencies
Annex A (normative) Tests
      A.1 General conditions for tests
      A.2 Additional requirements for testing reference
          ballasts
      A.3 Selection of reference lamps
      A.4 Measurement of open-circuit voltage
      A.5 Measurements of pre-heating conditions
      A.6 Measurement of lamp power and current
      A.7 Measurement of maximum current in any lead to
          a cathode
      A.8 Measurement of current waveform (Figure A.9)
      A.9 Measurement of impedance at audio-frequencies
Annex B (informative) Series operation of two fluorescent
         lamps
Annex C (normative) Reference ballasts
      C.1 Marking
      C.2 Design characteristics
      C.3 Operating characteristics
Annex D (normative) Reference lamps
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Bibliography

Provides performance requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz, associated with tubular fluorescent lamps with pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. Applies to complete ballasts and their component parts such as resistors, transformers and capacitors.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Current

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.