SN EN 61217 : 1996 AMD 1 2001
Current
The latest, up-to-date edition.
RADIOTHERAPY EQUIPMENT - COORDINATES, MOVEMENTS AND SCALES
12-01-2013
INTRODUCTION
1 Scope and object
2 Coordinate systems
2.1 General rules
2.2 Fixed reference system ("f") (figure 1a)
2.3 Gantry coordinate system ("g") (figure 4)
2.4 Beam limiting device or delineator coordinate
system ("b")(figure 5)
2.5 Wedge filter coordinate system ("w")(figure 7)
2.6 X-ray image receptor coordinate system ("r")
(figures 6 and 8)
2.7 Patient support coordinate system ("s")(figure 9)
2.8 Table top eccentric rotation coordinate system
("e")(figures 10 and 11)
2.9 Table top coordinate system ("t")(figures 10
and 11)
3 Identification of scales and digital displays
4 Designation of equipment movements
5 Equipment zero positions
6 List of scales, graduations, directions and displays
6.1 Rotation of the gantry (figures 14a and 14b)
6.2 Rotation of the beam limiting device or
delineator (figures 15a and 15b)
6.3 Rotation of the wedge filter (figures 7 and 14a)
6.4 Radiation field or delineated radiation field
6.5 Patient support isocentric rotation
6.6 Table top eccentric rotation
6.7 Tabler top linear movements
6.8 X-ray image receptor movements
6.9 Other scales
Tables
1 Equipment movements and designations
2 Individual coordinate systems
Figures
1a Coordinate systems (see 2.1.2) with all angular
positions set to zero
1b Translation of origin Id along Xm, Ym, Zm and rotation
around axis Zd parallel to Zm (see 2.1.4)
1c Translation of origin Id along Xm, Ym, Zm and rotation
around axis Yd parallel to Ym (see 2.1.4)
2 X Y Z right-hand coordinate mother system (isometric
drawing), showing directions of positive rotation for
daughter system (see 2.2)
3 Hierarchical structure among coordinate systems (see
2.1.3 and 2.1.5)
4 Rotation of gantry coordinate system Xg, Yg, Zg in
fixed coordinate system Xf, Yf, Zf (see2.3)
5 Rotation of beam limiting device or delineator
coordinate system Xb, Yb, Zb in gantry coordinate system
Xg, Yg, Zg and resultant rotation of radiation field or
delineated radiation field of dimensions FX and FY (see2.4)
6 Displacement of image intensifier type X-ray image
receptor coordinate system origin Ir, in gantry coordinate
system, by Rx=-8, Ry=+10, RZ=-40 (see 2.60)
7 Rotation (O2=270 deg) and translation of wedge filter
coordinate system Xw, Yw, Zw in beam limiting device
coordinate system Xb, Yb, Zb, the beam limiting device
coordinate system having a rotation (Ob) of 345 deg (see 2.5)
8 Rotation (Or=90 deg) and displacement of radiographic
cassette type X-ray image receptor coordinate system Xr,
Yr, Zr in gantry coordinate system Xg, Yg, Zg (see 2.6)
9 Rotation (Or=345 deg) of patient support coordinate system
Xs, Yx, Zs in fixed coordinate system Xf, Yf, Zf (see 2.7)
10 Table top eccentric coordinate system rotation Oe in
patient support coordinate system which has been rotated
by 0s in the fixed coordinate system with 0e=360 deg-0s
(see 2.8 and 2.9)
11a Table top displaced below isocentre by Tz=-20cm (see 2.8
and 2.9)
11b Table top coordinate system displacement Tx=+5, Ty=Le
+ 10 in patient support coordinate system Xs,Ys,Zs
rotation (0s=330 deg) in fixed coordinate system Xf,Yf,Zf
(see 2.8 and 2.9)
11c Table top coordinate system rotation (0e=30 deg) about
table top eccentric system. Patient support rotation
(0s=330 deg) in fixed coordinate system Tx=O, Ty=Le
(see 2.8 and 2.9)
12a Example of beam limiting device scale, pointer on mother
system (gantry) scale on daughter system (beam limiting
device), viewed from isocentre (see 2.1.6.2 and clause 3)
12b Examples of beam limiting device scale, pointer on
daughter system (beam limiting device) scale on mother
system (gantry), viewed from isocentre (see 2.1.6.2 and
clause 3)
12c Examples of scales (see clause 3)
13a Rotary gantry (adapted from IEC 601-2-1) with
identification of axes 1 to 8, directions 9 to 13 and
dimensions 14 and 15 (see clause 4)
13b Isocentric radiotherapy simulator or teleradiotherapy
equipment, with identification of axes 1;4 to 6, 19, of
directions 9 to 12; 16 to 18 and of dimensions 14; 15;
20 to 23 (clause 4)
13c View from radiation source of teleradiotherapy radiation
field or radiotherapy simulator delineated radiation field
(see clause 4)
14a Example of isocentric teleradiotherapy equipment
(see 6.1 and 6.3)
14b Example of isocentric radiotherapy simulator equipment
(see 6.1)
15a Rotated (0b=30deg) symmetrical rectangular radiation field
(FX x FY) at normal treatment distance, viewed from
Radiation Source (see 6.2)
15b Same rotated (0b=30deg) symmetrical rectangular
radiation field (FX x FY) at normal treatment distance
viewed from radiation source (see 6.2)
16a Rectangular and symmetrical radiation field or
delineated radiation field, viewed from radiation source
(see 6.4)
16b Rectangular and asymmetrical in Yb radiation field or
delineated radiation field, viewed from radiation source
(see 6.4)
16c Rectangular and asymmetrical in Xb radiation field or
delineated radiation field, viewed from radiation source
(see 6.4)
16d Rectangular and asymmetrical in Xb and Yb radiation field
or delineated radiation field, viewed from radiation
source (see 6.4)
16e Rectangular and asymmetrical in Yb radiation field,
rotated by 0b=30 deg, viewed from radiation source (see 6.4)
16f Rectangular and asymmetrical in Yb radiation field,
rotated by 0b=30 deg, viewed from radiation source (see 6.4)
16g Rectangular and asymmetrical in Xb radiation field,
rotated by 0b=30deg, viewed from radiation source (see 6.4)
16h Rectangular and asymmetrical in Xb and Yb radiation
field, rotated by 0b=30 deg, viewed from radiation source
16i Irregular multi-element (multileaf) contiguous radiation
field, with element motion in Xb direction (see 6.4)
16j Irregular multi-element (multileaf) two-part radiation
field, viewed from radiation source, with element motion
in Xb direction (see 6.4)
16k Irregular multi-element (multileaf) contiguous radiation
field, viewed from radiation source, with element motion
in Yb direction (see 6.4)
Annexes
A Examples of coordinate transformations between individual
coordinate systems
B Bibliography
C Rationale for changes in IEC scales
D Summary of additions and changes to scale statements in
IEC 601-2-1, IEC 601-2-11, IEC 975 and IEC 977
E Terminology
Applicable to equipment and data related to the process of teleradiotherapy. Includes patient image data relative to radiotherapy treatment planning systems, simulators, isocentric gamma beam therapy equipment, isocentric medical electron accelerators, and non-isocentric equipment where relevant. Specifies a consistent set of coordinate systems to be used throughout the teleradiotherapy process to specify the marking of scales where applicable for definition of the movements of equipment in this process and to facilitate computer control if used.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Current
|
Standards | Relationship |
EN 61217:2012 | Identical |
DIN EN 61217:2015-11 | Identical |
UNE-EN 61217:1999 | Identical |
BS EN 61217:2012 | Identical |
I.S. EN 61217:2012 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.