SN EN 62005-2 : 2001
Current
The latest, up-to-date edition.
RELIABILITY OF FIBER OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PART 2: QUANTITATIVE ASSESSMENT OF RELIABILITY BASED ON ACCELERATED AGEING TESTS; TEMPERATURE AND HUMIDITY, STEADY STATE
12-01-2013
FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Guidance on testing for wear out failures
3.1 Failure distribution
3.2 Median time to failure (MTF)
4 Life test matrix
5 Worked example
5.1 Test condition matrix
5.2 Analysis of results
5.3 Calculating median time to failure
5.4 Calculation of temperature acceleration factor
5.5 Calculation of humidity acceleration factor
5.6 Extrapolation to service conditions
5.7 Calculation of failure rate
6 Random failure rate calculations
7 Implications for system reliability
Useful for defining reliability tests for passive optical components. It gives advice on life testing procedures, the calculation of failure rates and the presentation of results. Also illustrates the method of calculating the instantaneous failure rate for a device during its service lifetime, based on accelerated life tests.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Current
|
Standards | Relationship |
BS EN 62005-2:2001 | Identical |
EN 62005-2:2001 | Identical |
IEC 62005-2:2001 | Identical |
UNE-EN 62005-2:2002 | Identical |
I.S. EN 62005-2:2001 | Identical |
DIN EN 62005-2:2002-02 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.