1 Introduction
1.1 Purpose
1.2 MODIFICATIONS OF TEST PROCEDURES WITH
              PUBLICATION OF ISSUE 3 OF TR-NWT-000397
1.3 Scope
1.4 Document Organization
1.5 Bellcore TR-NWT-000397 Requirements Mapping
              to Test Plan
2 LULT (LT-like Line Unit) Layer 1 Conformance
              Testing
2.1 Layer 1 Test Summary
2.2 LULT Cold Start Verification [TR-NWT-000393,
              Section 5.10.7.7]
2.3 LULT Cold Start Failure [TR-NWT-000393,
              Section 5.10.4]
2.4 TL and SL1 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
2.5 SL2 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
2.6 SL3 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
2.7 LULT Initiated Activation [TR-NWT-000393,
              Section 5.10.7.3]
2.8 LULT Warm Start Verification [TR-NWT-000393,
              Section 5.10.7.7]
2.9 Transceiver Retraining Verification
              [TR-NWT-000393, Section 5.10.1.4]
2.10 Loss-of-Synchronization [TR-NWT-000393,
              Section 5.10.4]
2.11 Loss-of-Received-Signal [TR-NWT-000393,
              Section 5.10.4]
2.12 Return Loss [TR-NWT-000393, Section 6.2.1]
2.13 Longitudinal Output Voltage [TR-NWT-000393,
              Section 6.2.6]
2.14 Longitudinal Balance [TR-NWT-00393, Section 6.2.8]
2.15 LULT dc Test Signature [TR-NWT-000397, Section 4.8.2]
2.16 LULT Sealing Current Application [TR-NWT-000397,
              Section 2.6.8]
2.17 Pulse Shape [TR-NWT-000393, Section 5.2.1.1]
2.18 Pulse Linearity [TR-NWT-000393, Section 5.9]
2.19 Power Spectral Density (PSD) [TR-NWT-000393,
              Section 5.2.2.1]
2.20 Total Power Output [TR-NWT-000393, Section 5.2.2.2]
2.21 LULT Transceiver Output Jitter [TR-NWT-000393,
              Section 5.5.4]
2.22 LULT Receiver Performance [TR-NWT-000393, App.C]
2.23 Baud Rate Verification (Sync With the Network)
              [TR-NWT-000397, Section 4.9]
2.24 LUNT-to-LULT Transmission Delay [TR-NWT-000397, 6.6]
3 LUNT (NT1-like Line Unit) Layer 1 Conformance
              Testing
3.1 Layer 1 Test Summary
3.2 LUNT Cold Start Verification [TR-NWT-000393,
              Section 5.10.7.7]
3.3 LUNT Cold Start Failure [TR-NWT 000393,
              Section 6.10.4]
3.4 TN and SN1 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
3.5 SN2 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
3.6 SN3 Signal Verification [TR-NWT-000393,
              Section 5.10.5]
3.7 LUNT Initiated Activation [TR-NWT-000393,
              Section 5.10.7.3]
3.8 SN2 Temporal Verification [TR-NWT-000393,
              Section 5.10.5]
3.9 LUNT Warm Start Verification [TR-NWT-000393,
              Section 5.10.7.7]
3.10 Transceiver Retraining Verification [TR-NWT-000393,
              Section 5.10.1.4]
3.11 Loss-of-Synchronization [TR-NWT-000393,
              Section 5.10.4]
3.12 Loss-of-Received Signal [TR-NWT-000393,
              Section 5.10.4]
3.13 Return Loss [TR-NWT-000393, Section 6.2.1]
3.14 Longitudinal Output Voltage [TR-NWT-000393,
              Section 6.2.6]
3.15 Longitudinal Balance [TR-NWT-000393, Section 6.2.8]
3.16 LUNT dc Test Signature [TR-NWT-000397,
              Section 6.8.1]
3.17 Pulse Shape [TR-NWT-000393, Section 5.2.1.1]
3.18 Pulse Linearity [TR-NWT-000393, Section 5.9]
3.19 Power Spectral Density (PSD) [TR-NWT-000393,
              Section 5.2.2.1]
3.20 Total Power Output [TR-NWT-000393, Section 5.2.2.2]
3.21 LUNT Transceiver Output Jitter [TR-NWT-000393,
              Section 5.5.4]
3.22 LUNT Receiver Performance [TR-NWT-000393, App.C]
3.23 Baud Rate Verification (Sync With the Network)
              [TR-NWT-000397, Section 6.9]
3.24 LULT-to-LUNT Transmission Delay
              [TR-NWT-000397, Section 4.6.2]
4 LULT (LT-like Line Unit) Conformance Testing
4.1 LULT DSL Master Transceiver Function
              [TR-NWT-000397, 4.2]
4.2 Multiplexed ISDN Basic Access & Operations
              Communications [TR-NWT-000397, Section 4.3]
4.3 DSL Embedded Operations Channel and the LULT
              [TR-NWT-000397, Section 4.4]
4.4 NT1 Power Status Bits [TR-NWT-000397, Section 4.5.1]
4.5 Start-up Bit [TR-NWT-000397, Section 4.5.2]
4.6 Turn-off Bit [TR-NWT-000397, Section 4.5.3]
4.7 NT1 in Test Mode Bit [TR-NWT-000397, Section 4.5.4]
4.8 Network Indicator Bit [TR-NWT-000397, Section 4.5.5]
4.9 Cold Start Only Bit [TR-NWT-000397, Section 4.5.6]
4.10 U-Interface-Only Activation Bit [TR-NWT-000397,
              Section 4.5.7]
4.11 S/T-Interface Activity Bit [TR-NWT-000397,
              Section 4.5.8]
4.12 Alarm Indicator Bit [TR-NWT-000397, Section 4.5.9]
4.13 Reserved Indicator Bits [TR-NWT-000397, Section 4.5.10]
4.14 Confirming State Change of Indicator Bits
              [TR-NWT-000397, Section 4.5.11]
4.15 Idle Code [TR-NWT-000397, Section 4.5.12]
4.16 LULT-NT1 DSL Transport System Performance
              [TR-NWT-000397, Section 4.6]
4.17 LULT Interim Performance Monitoring
              [TR-NWT-000397, Section 4.7.2]
4.18 Checking Performance Monitoring [TR-NWT-000397,
              Section 4.7.3]
4.19 LULT dc Test Signature [TR-NWT-000397, Section 4.8.2]
4.20 Loopbacks for LULTs [TR-NWT-000397, Section 4.8.3]
4.21 Alarm Conditions [TR-NWT-000397, Section 4.8.4]
4.22 LULT DSL Synchronization with the Network
              [TR-NWT-000397, Section 4.9]
4.23 Sealing Current Provisioning [TR-NWT-000397,
              Section 4.10]
4.24 LULT DF DSL Start-up [TR-NWT-000397, Section 4.11]
5 LUNT (NT1-like Line Unit) Conformance Testing
5.1 LUNT DSL Slave Transceiver Function
              [TR-NWT-000397, Section 6.2]
5.2 Multiplexed ISDN Basic Access & Operations
              Communications [TR-NWT-000397, Section 6.3]
5.3 DSL Embedded Operations Channel and the LUNT
              [TR-NWT-000397, Section 6.4]
5.4 NT1 Power Status Bits [TR-NWT-000397, Section 6.5.1]
5.5 Start-up Bit [TR-NWT-000397, Section 6.5.2]
5.6 Turn-off Bit [TR-NWT-000397, Section 6.5.3]
5.7 NT1 in Test Mode Bit [TR-NWT-000397, Section 6.5.4]
5.8 Network Indicator Bit [TR-NWT-000397, Section 6.5.5]
5.9 Cold Start Only Bit [TR-NWT-000397, Section 6.5.6]
5.10 U-Interface-Only Activation Bit
              [TR-NWT-000397, Section 6.5.7]
5.11 S/T-Interface Activity Bit [TR-NWT-000397,
              Section 6.5.8]
5.12 Alarm Indicator Bit [TR-NWT-000397, Section 6.5.9]
5.13 Reserved Indicator Bits [TR-NWT-000397, Section 6.5.10]
5.14 Confirming State Change of Indicator Bits
              [TR-NWT-000397, Section 6.5.11]
5.15 Idle Code [TR-NWT-000397, Section 6.5.12]
5.16 LT-LUNT DSL Transport System Performance
              [TR-NWT-000397, Section 6.6]
5.17 LUNT Interim Performance Monitoring
              [TR-NWT-000397, Section 6.7.2]
5.18 Checking Performance Monitoring Function
              [TR-NWT-000397, Section 6.7.3]
5.19 LUNT dc Test Signature [TR-NWT-000397, Section 6.8.1]
5.20 Loopbacks for LUNTs [TR-NWT-000397, Section 6.8.2]
5.21 Alarm Conditions [TR-NWT-000397, Section 6.8.3]
5.22 Return to Normal State [TR-NWT-000397, Section 6.8.4]
5.23 Hold State [TR-NWT-000397, Section 6.8.5]
5.24 Unable to Comply [TR-NWT-000397, Section 6.8.6]
5.25 LUNT DSL Synchronization with the Network
              [TR-NWT-000397, Section 6.9]
5.26 LUNT DF DSL Start-up [TR-NWT-000397, Section 6.10]
6 3-DS0 TDM Interface Conformance Testing
6.1 3-DS0 TDM Mapping of 2B+D and M Channel Bits
              [TR-NWT-000397, Section 10.2.1]
6.2 Zero Byte Substitution/Recovery Option
              [TR-NWT-000397, Section 10.2.2]
6.3 The 3-DS0 Superframe [TR-NWT-000397,
              Section 10.2.4]
6.4 Coordination of DSL and 3-DS0 Superframes
              [TR-NWT-000397, Section 10.2.5]
6.5 M Bit Definitions Within the D+ Channel
              [TR-NWT-000397, Section 10.2.6]
7 Multipoint Embedded Operations Channel
              Conformance Testing
7.1 Relative Addressing on the mp-eoc
              [TR-TSY-000829, Section 11.3.2.1]
7.2 mp-eoc Command/Response Mode [TR-TSY-000829,
              Section 11.3.2.2]
7.3 mp-eoc Data Write Mode
7.4 mp-eoc Data Read Mode
7.5 Loss of Synchronization Word
8 ISDN LUNT/LULT Miscellaneous Test Results
8.1 LUNT/LULT Channel Unit Power Consumption
              [Vendor's Claims, TR-NWT-000063]
8.2 LUNT/LULT Channel Unit Operation - D4 Power
              Supply Deviation [No Reqs.]
8.3 D4 Channel Bank Yellow Alarm and 3-DS0 D+ Channel
              [TR-NWT-000397, Section 10.2.1]
8.4 LUNT/LULT Channel Unit Insertion/Extraction
              [No Reqs]
8.5 LUNT/LULT Channel Unit Support of MLT/PGTC
              Test Procedures [TR-TSY-
References

Establishes a test plan for Line Unit Network Termination (LUNT) and a Line Unit Line Termination (LULT) for use in Universal Digital Loop Carrier (UDLC) and Universal Digital Channel Bank (UDCB) Central Office Terminals (COTs) and Remote Digital Terminals (RDTs), respectively. The objective of the test plan is to identify LULT/LUNT Characteristics that, in Telcordia's view, will satisfactorily support operation of ISDN BRA through a UDLC or UDCB system (over a T1 Carrier facility), and help ensure a high degree of operability of the LUNT with multiple switch suppliers' LTs (including the switch operations system that supports this LT).

DocumentType
Standard
PublisherName
Telcordia Technologies
Status
Current

SR 3859 : ISSUE 1 CERTIFICATION OF THE PHYSICAL LAYER OF ISDN BASIC ACCESS NETWORK TERMINATION AND LINE TERMINATION EQUIPMENT

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.