UL 296:11ED 2017-02-24

Current

Current

The latest, up-to-date edition.

Oil Burners

Available format(s)

Hardcopy

Published date

24-02-2017

€965.88
Excluding VAT

Foreword
Introduction
1 Scope
2 Units of measurements
3 Components
4 Glossary
Construction - mechanical
5 General
6 Servicing
7 Assembly
8 Bases
9 Fan housings and air tubes
10 Fire pots and vaporizers
11 Combustion air controls
12 Prepurge and post-purge
13 Draft regulators
14 Strainers
15 Constant-level devices
16 Floats
17 Fittings, and piping and tubing
18 Valves
19 Stuffing boxes
20 Gauges
21 Gas pilots
22 Manually-lighted burners
23 Antiflooding devices
Construction - electrical
24 Servicing and adjustment
25 Ignition systems
26 Electric high-tension ignition
27 Electric hot-wire ignition
28 Control applications
29 Primary safety controls
30 Electrical equipment
31 Field wiring
32 Internal wiring
33 Overcurrent protection of high-voltage control-
    circuit conductors
34 Overcurrent protection of transformers
35 Separation of circuits
36 Accessibility
37 Bonding for grounding
38 Mounting of electrical components
39 Electrical enclosures
40 Motors and motor overload protection
41 Switches and controllers
42 Capacitors
43 Electrical insulating material
44 Spacings - high-voltage circuits
45 Spacings - low-voltage circuits
46 Combination gas-oil burners
Performance
47 General
48 Measurements
49 Test voltage
50 Combustion tests
51 Combustion air failure test - test no. 3
52 Interruption of atomization - test no. 4
53 Undervoltage test - test no. 5
54 Power interruption test - test no. 6
55 Temperature test - test no. 7
56 Ignition tests, multiple ignitors
57 Ignition tests, electric high-tension
58 Ignition test, electric hot-wire
59 Ignition tests, gas
60 Ignition test, gas-electric - test no. 18
61 Ignition test, gas-electric high-tension
62 Ignition tests, gas-electric hot-wire
63 Ignition tests, manual
64 Ignition test, multiple-atomizer burner - test no.
    26
65 Ignition tests, multiple-vaporizer burner - test no.
    27
66 Return of ignition - test no. 27A
67 Seepage and burnoff test - test no. 28
68 Dielectric voltage-withstand test - test no. 20
69 Short circuit test - test no. 30
70 Overload test, high-voltage transformers
71 Burnout test, high-voltage transformers
Manufacturing and production tests
72 General
Marking
73 General
74 Instructions
Appendix
A Standards for components

This revision of ANSI/UL 296 dated January 8, 2021 includes Flexible Connector Piping for Fuels; 18.11

DevelopmentNote
NEW CHILD REV 2 2020 IS NOW ADDED NEW CHILD REV 3 2021 IS NOW ADDED
DocumentType
Standard
Pages
0
ProductNote
NEW CHILD REV 2 2020 IS NOW ADDED NEW CHILD REV 3 2021 IS NOW ADDED
PublisherName
Underwriters Laboratories
Status
Current

These requirements cover oil burners intended for firing appliances and devices such as boilers; central, floor, wall, and special furnaces; storage tank water, air, and direct-fired air heater units; and ovens.

MIL-H-12394 Revision D:1976 HEATERS, WATER, LIQUID FUEL
MIL-B-23170 Revision A:1978 BOILERS, STEAM, HIGH PRESSURE WATER TUBE, PACKAGED TYPE (5,000 TO 50,000 POUNDS PER HOUR, FIRED BY COAL, OIL, GAS OR COMBINATION OIL/GAS)
MIL-B-18796 Revision F:1984 BURNERS, SINGLE: OIL, GAS, AND GAS-OIL COMBINATION FOR PACKAGED BOILERS (320,001 TO 125,000,000 BTU/HR THERMAL OUTPUT CAPACITY)
MIL-PRF-32046 Base Document:2003 RATION HEATING UNIT, FIELD FEEDING
F-B-2910 Base Document:1998 BURNERS, SINGLE: OIL, GAS, AND GAS-OIL COMBINATION FOR PACKAGED BOILERS (320,001 TO 125, 000,000 BTU/HR THERMAL OUTPUT CAPACITY)
WW-F-2743 Revision A:1998 FURNACES, WARM AIR & HEATERS, UNIT, FORCED AIR CIRCULATION, OIL & GAS FIRED
UL 795:8ED 2016-12-02 Commercial-Industrial Gas Heating Equipment
ASME CSD1 : 2012 CONTROLS AND SAFETY DEVICES FOR AUTOMATICALLY FIRED BOILERS
UL 2106:2ED 2006-04-18 Standard for Field Erected Boiler Assemblies
NFPA 31 : 2016 INSTALLATION OF OIL-BURNING EQUIPMENT
UL 391:5ED 2010-09-10 Standard for Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces
UL 731:6ED 2018-01-31 Oil-Fired Unit Heaters
ASHRAE HDBK REFRIGERATION : 2014 ASHRAE HANDBOOK - REFRIGERATION

UL 514A:11ED 2013-02-01 Metallic Outlet Boxes
UL 5085-3:1ED 2006-04-17 Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers
UL 506:14ED 2017-06-02 Specialty Transformers
UL 343:9ED 2008-12-17 Pumps for Oil-Burning Appliances
UL 83:16ED 2017-07-28 Standard for Thermoplastic-Insulated Wires and Cables
UL 4248-9:1ED 2007-02-28 Fuseholders - Part 9: Class K
UL 514C:4ED 2014-04-08 Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers
UL 372:6ED 2007-07-31 Automatic Electrical Controls for Household and Similar Use - Part 2: Particular Requirements for Burner Ignition Systems and Components
UL 429:7ED 2013-11-06 Electrically Operated Valves
UL 60730-1:5ED 2016-08-03 Automatic Electrical Controls - Part 1: General Requirements
UL 2250:3ED 2017-03-30 Instrumentation Tray Cable
UL 248-5:2ED 2000-08-01 Low-Voltage Fuses - Part 5: Class G Fuses

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.