UNE-CLC/TS 50576:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Electric cables - Extended application of test results for reaction to fire
Hardcopy , PDF
Spanish, Castilian, English
06-09-2017
20-12-2023
This Technical Specification gives the procedure and rules for extended application of results of tests
carried out according to the test methods described in EN 50399, EN 60332-1-2 and EN 61034-2.
The EXAP rules described apply to EN 50399 test results used for classification in classes B2ca,Cca
and Dca, additional smoke production classes s1, s2 and s3 and flaming droplets/particles, to
EN 60332-1-2 test results used for classification in classes B2ca,Cca, Dca and Eca and to EN 61034-2
test results used for classification in classes s1a and s1b.
Cables of diameter 5,0 mm and less should be tested as bundles according to EN 50399 and are
excluded from these rules. Bundled cables are not included in the EXAP rules applying to EN 50399
test results.
The rules apply to circular and non-circular cables provided that they fall within the scope of the
relevant test method.
A specific EXAP rule has been developed for the most common generic power cable families and
optical fibre cables. A general EXAP rule has been developed for any power cable families. The
general EXAP rule is not applicable to communication or optical fibre cables.
NOTE 1 Multicore power cables with more than 5 cores are sometimes referred to as control cables with a
rated voltage but for the purposes of this standard are considered as power cables.
The general EXAP rule may be applied in the case of hybrid cables provided that the conditions of 6.1
are fulfilled.
The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range
of cable constructions (product family).
An EXAP is only possible when cables belong to a defined family as defined in this Technical
Specification.
NOTE 2 No EXAP procedure and rules have been developed in respect of the results of tests carried out
according to the test method described in EN 60754 2. As the parameters (pH and conductivity) for each cable in
a family are determined based upon calculation using material test results, this is considered as a matter of direct
application. Material test results taken from any one sample of finished cable from a family are sufficient to
calculate the parameters for each cable in the family.
| Committee |
CTN 211/SC 20
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Superseded
|
| Supersedes |
| Standards | Relationship |
| CLC/TS 50576:2016 | Identical |
| EN 50399 : 2011 AMD 1 2016 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
| IEC 60228:2004 | Conductors of insulated cables |
| EN 13501-6:2014 | Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables |
| EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
| EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
| EN 50575:2014/A1:2016 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
| IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
| EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
| CEN/TS 15117:2005 | Guidance on direct and extended application |
| IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.