UNE-EN 13598-2:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers
Hardcopy , PDF
Spanish, Castilian, English
14-06-2017
09-03-2022
This European Standard specifies the definitions and requirements for buried manholes and inspection chambers installed to a maximum depth of 6 m from ground level to the invert of the main chamber and manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE). These products are intended for use in pedestrian or vehicular traffic areas and underground installations conforming to the general requirements given in EN 476 and are used outside the building structure (application area code U ). They are therefore marked accordingly with a U . Such products are also deemed to meet the requirements of EN 13598-1 for application area U without the need for further testing. If additionally marked application area D then these products must additionally be tested to show compliance to the elevated temperature cycling requirement of Clause 10 of EN 13598-1.
This European Standard is only applicable to those chamber / manhole components where the manufacturer has clearly stated in the documentation how the components shall be assembled to create a complete manhole or inspection chamber.
The inspection chambers and manholes covered by this European Standard comprise the following:
¾ðinspection chambers providing access to the drainage or sewerage system by means of inspection and cleaning equipment.
¾ðmanholes providing man access additionally to the drainage or sewerage system.
¾ðthese inspection chambers and manholes may also be used for storm-water systems
This European standard only covers product with flow profiling
Note 1 - Shallow inspection chambers for use in non-roadway situations down to a depth of 1.25 m max are specified in EN 13598-1.
Note 2 - The frame, cover or grating is not covered by this specification they shall, unless otherwise specified, conform to the appropriate design in EN 124 or ISO 15398
The inspection chamber / manhole components can be manufactured by various methods e.g. injection moulding, rotational moulding, low-pressure moulding or fabricated from components made in accordance with other standards.
The jointing of components can be achieved using:
¾ðelastomeric ring seal joints;
¾ðadhesive joints for PVC-U;
¾ðwelded joints for PVC-U, PP and PE;
¾ðextrusion welding;
¾ðmechanical jointing.
NOTE Both manholes and inspection chambers can be site assembled from different components, but can also be manufactured as a single unit. In either case, the following functional parts can be recognized:
a) base(always present)
In case of a one-piece chamber or manhole, the base part ends at a distance of 300 mm measured from the top of the main channel;
b) riser(depth dependent);
c) telescopic part(design dependent);
d) cone(dependent on the design of near surface components and their recommended installation);
e) other near surface components
| Committee |
CTN 53/SC 2
|
| DocumentType |
Standard
|
| Pages |
31
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Superseded
|
| Standards | Relationship |
| EN 13598-2:2016 | Identical |
| ISO 15493:2003 | Plastics piping systems for industrial applications — Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) — Specifications for components and the system — Metric series |
| ISO 580:2005 | Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating |
| EN ISO 3126:2005 | Plastics piping systems - Plastics components - Determination of dimensions (ISO 3126:2005) |
| EN 14396:2004 | Fixed ladders for manholes |
| EN ISO 13229:2011 | Thermoplastics piping systems for non-pressure applications - Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings - Determination of the viscosity number and K-value (ISO 13229:2010) |
| ISO 13259:2010 | Thermoplastics piping systems for underground non-pressure applications — Test method for leaktightness of elastomeric sealing ring type joints |
| EN 124-2:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 2: Gully tops and manhole tops made of cast iron |
| ISO 13229:2010 | Thermoplastics piping systems for non-pressure applications — Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings — Determination of the viscosity number and K-value |
| EN 13598-1:2010 | Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings including shallow inspection chambers |
| ISO 15494:2015 | Plastics piping systems for industrial applications — Polybutene (PB), polyethylene (PE), polyethylene of raised temperature resistance (PE-RT), crosslinked polyethylene (PE-X), polypropylene (PP) — Metric series for specifications for components and the system |
| EN ISO 9967:2016 | Thermoplastics pipes - Determination of creep ratio (ISO 9967:2016) |
| ISO 13263:2010 | Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics fittings — Test method for impact strength |
| ISO 13267:2010 | Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics inspection chamber and manhole bases — Test methods for buckling resistance |
| ISO 1133-1:2011 | Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics — Part 1: Standard method |
| EN ISO 15494:2015 | Plastics piping systems for industrial applications - Polybutene (PB), polyethylene (PE), polyethylene of raised temperature resistance (PE-RT), crosslinked polyethylene (PE-X), polypropylene (PP) - Metric series for specifications for components and the system (ISO 15494:2015) |
| EN 1253-4:2016 | Gullies for buildings - Part 4: Access covers |
| ISO 3127:1994 | Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method |
| ISO 3126:2005 | Plastics piping systems — Plastics components — Determination of dimensions |
| EN 476:2011 | General requirements for components used in drains and sewers |
| EN ISO 1133-1:2011 | Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics - Part 1: Standard method (ISO 1133-1:2011) |
| ISO 13266:2010 | Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of resistance against surface and traffic loading |
| EN 14758-1:2012 | Plastics piping systems for non-pressure underground drainage and sewerage - Polypropylene with mineral modifiers (PP-MD) - Part 1: Specifications for pipes, fittings and the system |
| EN 124-6:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U) |
| ISO 1183-1:2012 | Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pyknometer method and titration method |
| EN 12666-1:2005+A1:2011 | Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system |
| ISO 1183-2:2004 | Plastics — Methods for determining the density of non-cellular plastics — Part 2: Density gradient column method |
| ISO 13268:2010 | Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of ring stiffness |
| EN 13101:2002 | Steps for underground man entry chambers - Requirements, marking, testing and evaluation of conformity |
| EN ISO 580:2005 | Plastics piping and ducting systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating (ISO 580:2005) |
| EN 1401-1:2009 | Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system |
| ISO 11357-6:2008 | Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) |
| ISO 9967:2016 | Thermoplastics pipes — Determination of creep ratio |
| EN 124-4:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 4: Gully tops and manhole tops made of steel reinforced concrete |
| EN 124-3:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 3: Gully tops and manhole tops made of steel or aluminium alloys |
| EN 124-5:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 5: Gully tops and manhole tops made of composite materials |
| ISO 1043-1:2011 | Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics |
| EN 124-1:2015 | Gully tops and manhole tops for vehicular and pedestrian areas - Part 1: Definitions, classification, general principles of design, performance requirements and test methods |
| EN ISO 1183-1:2012 | Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012) |
| EN ISO 1183-2:2004 | Plastics - Methods for determining the density of non-cellular plastics - Part 2: Density gradient column method (ISO 1183-2:2004) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.