• Shopping Cart
    There are no items in your cart

UNE-EN 50121-3-2:2017

Current

Current

The latest, up-to-date edition.

Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus

Available format(s)

Hardcopy , PDF

Published date

14-06-2017

€87.60
Excluding VAT

This European Standard applies to emission and immunity aspects of EMC for electrical and electronicapparatus intended for use on railway rolling stock. EN 50121-3-2 applies for the integration ofapparatus on rolling stock.The frequency range considered is from DC to 400 GHz. No measurements need to be performed atfrequencies where no requirement is specified.The application of tests shall depend on the particular apparatus, its configuration, its ports, itstechnology and its operating conditions.This standard takes into account the internal environment of the railway rolling stock and the externalenvironment of the railway, and interference to the apparatus from equipment such as hand-held radio transmitters.If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators,e.g. transponder systems), then the radiated emission requirement in this standard is not intended tobe applicable to the intentional transmission from a radio-transmitter as defined by the ITU.Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC relatedstandard for radio equipment.This standard does not apply to transient emissions when starting or stopping the apparatus.The objective of this standard is to define limits and test methods for electromagnetic emissions andimmunity test requirements in relation to conducted and radiated disturbances.These limits and tests represent essential electromagnetic compatibility requirements.Emission requirements have been selected so as to ensure that disturbances generated by theapparatus operated normally on railway rolling stock do not exceed a level which could prevent otherapparatus from operating as intended. The emission limits given in this standard take precedence overemission requirements for individual apparatus on board the rolling stock given in other standards.Likewise, the immunity requirements have been selected so as to ensure an adequate level ofimmunity for rolling stock apparatus.The levels do not however cover all cases which may occur with an extremely low probability ofoccurrence in any location. Specific requirements which deviate from this standard shall be specified.Test requirements are specified for each port considered.These specific provisions are to be used in conjunction with the general provisions in EN 50121-1.

Committee
CTN 203/SC 9X
DevelopmentNote
Supersedes UNE ENV 50121-3-2. (10/2003) NEW CHILD AMD 1 IS ADDED
DocumentType
Standard
Pages
27
ProductNote
NEW CHILD AMD 1 IS ADDED
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
DIN EN 50121-3-2 : 2017 Identical
BS EN 50121-3-2:2016 Identical
NEN EN 50121-3-2 : 2017 Identical
EN 50121-3-2:2016 Identical
I.S. EN 50121-3-2:2016 Identical

EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
EN 55016-2-3:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
EN 55016-1-4:2010/A2:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
EN 50121-1:2017 Railway applications - Electromagnetic compatibility - Part 1: General
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 50155:2017 Railway applications - Rolling stock - Electronic equipment
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
EN 50121-3-1:2017 Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle
EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-4-4:2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€87.60
Excluding VAT