• UNE-EN 61000-2-12:2004

    Current The latest, up-to-date edition.

    Electromagnetic compatibility (EMC) -- Part 2-12 : Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems

    Available format(s):  Hardcopy, PDF

    Language(s):  Spanish, Castilian, English

    Published date:  03-09-2004

    Publisher:  Asociacion Espanola de Normalizacion

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope and object
    2 Normative references
    3 Terms and definitions
       3.1 General definitions
       3.2 Phenomena related definitions
    4 Compatibility levels
       4.1 General comment
       4.2 Voltage fluctuations and flicker
       4.3 Harmonics
       4.4 Interharmonics and voltage components at
            frequencies above that of the 50[th] harmonic
       4.5 Voltage dips and short supply interruptions
       4.6 Voltage unbalance
       4.7 Transient overvoltages
       4.8 Temporary power frequency variation
       4.9 DC component
       4.10 Mains signalling
    Annex A (informative) The function of compatibility
            levels and planning levels in EMC
       A.1 The need for compatibility levels
       A.2 Relation between compatibility level and
            immunity levels
       A.3 Relation between compatibility level and
            emission limits
       A.4 Planning levels
       A.5 Illustration of compatibility, emission,
            immunity and planning levels
    Annex B (informative) Discussion of some disturbance
            phenomena
       B.1 Resolution of non-sinusoidal voltages and
            currents
       B.2 Interharmonics and voltage components at
            frequencies above that of the 50[th] harmonic
       B.3 Voltage dips and short supply interruptions
       B.4 Transient overvoltages
       B.5 DC component
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the conducted disturbances in the frequency range from 0 kHZ to 9 kHZ, with an extension up to 148,5 kHZ specifically for mains signalling systems.

    General Product Information - (Show below) - (Hide below)

    Committee CTN 208/SC 77-210
    Document Type Standard
    Publisher Asociacion Espanola de Normalizacion
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective