UNE-EN 61663-2:2003
Current
The latest, up-to-date edition.
Lightning protection - Telecommunication lines -- Part 2: Lines using metallic conductors.
Hardcopy , PDF
Spanish, Castilian, English
21-03-2003
FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Environmental factor Ke, installation factor Ki,
shielding factor Ks and conventional transition
point length LcT
5.1 Environmental factor Ke
5.2 Installation factor Ki
5.3 Shielding factor Ks
5.4 Conventional transition point length LcT
6 Protection need
6.1 General
6.2 Protection need against indirect lightning to
the telecommunication line
6.3 Protection need against direct lightning to the
structure that the telecommunication line enters
6.4 Protection need against direct lightning to the
telecommunication line
7 Protection measures
7.1 General
7.2 Protective measures against indirect lightning
to the telecommunication line
7.3 Protective measures against direct lightning to
the structure that the telecommunication line enters
7.4 Protective measures against direct lightning to
the telecommunication lines
Annex A (normative) Procedure for evaluating the
protection needs against lightning of
telecommunication or signal lines using
metallic conductors
Annex B (normative) Resistance value of the cable shield
connection to earth along the telecommunication
line
Annex C (normative) Evaluation of the lightning current
I striking the structure which causes damage
to the telecommunication line entering the structure
Annex D (informative) Overvoltages, overcurrents and
frequency of damage Fp on a telecommunication line
Annex E (informative) Relative amount of expected
losses per damage
Annex F (informative) Application of protection need
requirements: examples
Annex G (informative) Environmental factor Ke
Annex H (informative) Risk of damage Rp
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Pertains to protection against lightning of outdoor telecommunication lines using metallic conductors (for example, access networks, lines between buildings).
Committee |
CTN 207/SC 81
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Standards | Relationship |
NBN EN 61663-2 : 2001 | Identical |
DIN EN 61663-2 : 2002 | Identical |
NF EN 61663-2 : 2001 | Identical |
BS EN 61663-2:2001 | Identical |
EN 61663-2 : 2001 | Identical |
I.S. EN 61663-2:2001 | Identical |