UNE-EN 989:1996
Current
The latest, up-to-date edition.
Determination of the bond behaviour between reinforcing bars and autoclaved aerated concrete by the the "Push-Out" test
Hardcopy , PDF
Spanish, Castilian, English
12-08-1996
Foreword
1 Scope
2 Normative references
3 Principle
4 Apparatus
5 Test specimens
5.1 Sampling
5.2 Shape and size of test specimens
5.3 Number of test specimens
5.4 Preparation of test specimens
5.5 Conditioning of test specimens
6 Procedure
7 Test results
8 Test report
Specifies a method of determining the bond behaviour between reinforcing bars and autoclaved aerated concrete (AAC).
| Committee |
CTN 127
|
| DocumentType |
Standard
|
| Pages |
12
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| EN 989:1995 | Identical |
| BS EN 989:1996 | Identical |
| I.S. EN 989:1995 | Identical |
| NF EN 989 : 1995 | Identical |
| NBN EN 989 : 1995 | Identical |
| NS EN 989 : 1ED 1995 | Identical |
| NEN EN 989 : 1995 | Identical |