Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors (Endorsed by Asociación Española de Normalización in December of 2024.)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-12-2024

€76.00
Excluding VAT

This part of IEC 60034 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 that:

have a rated voltage up to 1 000 V;

are intended for direct-on-line or star-delta starting;

are rated on the basis of duty type S1;

are constructed to any degree of protection as defined in IEC 60034-5 and explosion protection.

This document also applies to dual voltage motors provided that the flux saturation level is the same for both voltages.

The values of torque, apparent power and current given in this document are limiting values (that is, minimum or maximum without tolerance).

NOTE 1 It is not expected that all manufacturers will produce machines for all eight designs. The selection of any specific design in accordance with this document will be a matter of agreement between the manufacturer and the

purchaser.

NOTE 2 Designs other than the eight specified may be necessary for particular applications.

NOTE 3 It should be noted that values given in manufacturers' catalogues may include tolerances in accordance with IEC 60034-1.

NOTE 4 The values tabled for locked rotor apparent power are based on r.m.s. symmetrical steady state locked rotor currents. The start of the motor leads to transient asymmetrical currents in the whole supply, so called inrush

currents, which may range from 1,8 to 2,8 times the steady state locked rotor value. The current peak and decay time are a function of the motor design and switching angle. Similar effects can occur during the switchover from

star to delta operation. A more detailed description is provided in Annex A.

NOTE 5 The application of the test methods described in clause 12 of this standard may be applied to cage induction motors outside the scope of this standard, as well. However, special care must be taken in such cases to

prevent overheating of the stator or the rotor winding depending on the concrete method and parameters chosen.

Committee
CTN 203/SC 2
DocumentType
Standard
Pages
34
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
BS EN IEC 60034-12:2024 Equivalent
IEC 60034-12:2024 Identical
EN IEC 60034-12:2024 Identical

€76.00
Excluding VAT