UNE-EN IEC 60071-2:2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Insulation co-ordination - Part 2: Application guidelines
Hardcopy , PDF
Spanish, Castilian, English
17-10-2018
17-07-2024
1.1 ScopeThis part of IEC 60071 constitutes an application guide and deals with the selection of insulation levels of equipment or installations for three-phase electrical systems. Its aim is to give guidance for the determination of the rated withstand voltages for ranges I and II of IEC 60071-1 and to justify the association of these rated values with the standardized highest voltages for equipment.This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this application guide.It covers three-phase systems with nominal voltages above 1 kV. The values derived or proposed herein are generally applicable only to such systems. However, the concepts presented are also valid for two-phase or single-phase systems.It covers phase-to-earth, phase-to-phase and longitudinal insulation.This application guide is not intended to deal with routine tests. These are to be specified by the relevant product committees.The content of this guide strictly follows the flow chart of the insulation co-ordination process presented in figure 1 of IEC 60071-1. Clauses 2 to 5 correspond to the squares in this flow chart and give detailed information on the concepts governing the insulation co-ordination process which leads to the establishment of the required withstand levels.The guide emphasizes the necessity of considering, at the very beginning, all origins, all classes and all types of voltage stresses in service irrespective of the range of highest voltaje for equipment. Only at the end of the process, when the selection of the standard withstand voltages takes place, does the principle of covering a particular service voltage stress by a standard withstand voltage apply. Also, at this final step, the guide refers to the correlation made in IEC 60071-1 between the standard insulation levels and the highest voltage for equipment.The annexes contain examples and detailed information which explain or support the concepts described in the main text, and the basic analytical techniques used.
| Committee |
CTN 207/SC 99
|
| DocumentType |
Standard
|
| Pages |
191
|
| ProductNote |
THIS STANDARD ALSO REFERS TO- CIGRE WG 33.02, CIGRE W.G. 13-02, CIGRE WG 33-07, CIGRE WG 33.03, CIGRE WG 33.06, CIGRE TF 33-03.03, CIGRE WG 33.01, CIGRE WG C4.306, CIGRE WG D1.03, CIGRE WG C4.302, CIGRE JWG A2/C4.39
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Superseded
|
| Supersedes |
| Standards | Relationship |
| EN IEC 60071-2:2018 | Identical |
| IEC 60071-2:1996 | Identical |
| IEC 60071-2:2018 | Identical |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.