UNE-EN IEC 60512-23-3:2019

Current

Current

The latest, up-to-date edition.

Connectors for electrical and electronic equipment - Tests and measurements - Part 23-3: Screening and filtering tests - Test 23c: Shielding effectiveness of connectors and accessories - Line injection method (Endorsed by Asociación Española de Normalización in April of 2019.)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-04-2019

€63.00
Excluding VAT

This part of IEC 60512 defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable.

NOTE 1 Ideally, the complete assembly should achieve a continuous 360° shielding capability throughout its length. Practically this is not always achievable based on the geometry of the connector.

NOTE 2 shielding is used in this document with the same meaning of screening .

This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested:

circular connectors;

rectangular connectors;

connectors for printed boards;

connector shielding accessories.

NOTE For the definition of accessory see IEV 581-24-10. A shielding accessory i.e. an accessory that confers shielding to a non-inherently shielded connector, may be a suitable set of shielded housings providing electrical continuity, along the mated connector set, between the screen of the (screened) cable at the cable outlet of the free cable connector housing and the metallic mounting surface for the fixed connector housing. The free connector housing is provided with a cable screen clamp.

This test method utilizes the principle that the intrinsic shielding property of the connector/ accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell.

This test method is based on two impedance-matched circuits. See figure 1 for the measurement principle. The connector specimen under test is integrated into the secondary circuit 02. The impedance-matched injection line of the primary circuit 01, which activates the electromagnetic field, runs parallel to the surface of the specimen under test.

This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems.

NOTE This standard has been adopted by ASD-STAN (formerly known as AECMA) as EN 2591-212 and, as such, should not be amended without direct consultation and liaison with the ASD-STAN organization.

Committee
CTN 209/SC 48
DocumentType
Standard
ISBN
978-2-8322-6319-8
Pages
22
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
IEC 60512-23-3:2018 Identical
EN IEC 60512-23-3:2019 Identical