UNE-EN IEC 60904-7:2020
Current
The latest, up-to-date edition.
Photovoltaic devices - Part 7: Computation of the spectral mismatch correction for measurements of photovoltaic devices
Hardcopy , PDF
English, Spanish, Castilian
30-09-2020
This part of IEC 60904 describes the procedure for correcting the spectral mismatch error introduced in the testing of a photovoltaic device, caused by the mismatch between the test spectrum and the reference spectrum and by the mismatch between the spectral responsivities (SR) of the reference device and of the device under test and therewith reduce the systematic uncertainty. This procedure is valid for single-junction devices but the principle may be extended to cover multi-junction devices.
The purpose of this standard is to give guidelines for the correction of the spectral mismatch error, should there be a spectral mismatch between the test spectrum and the reference spectrum as well as between the reference device SR and the device under test SR.
Since a PV device has a wavelength-dependent spectral responsivity, its performance is significantly affected by the spectral distribution of the incident radiation, which in natural sunlight varies with several factors such as location, weather, time of year, time of day, orientation of the receiving surface, etc., and with a simulator varies with its type and conditions. If the irradiance is measured with a thermopile-type radiometer (that is not spectrally selective) or with a PV reference device, the spectral irradiance distribution of the incoming light must be known to make the necessary corrections to obtain the performance of the PV device under the reference spectral irradiance distribution defined in IEC 60904-3.
If a reference PV device or a thermopile type detector is used to measure the irradiance, then, following the procedure given in this standard, it is possible to calculate the spectral mismatch correction necessary to obtain the short-circuit current of the device under test under the reference spectral irradiance distribution in IEC 60904-3 or any other reference spectrum. If the reference PV device has the same relative spectral responsivity as the device under test then the reference device automatically takes into account deviations of the measured spectral irradiance distribution from the reference spectral irradiance distribution, and no further correction of spectral mismatch errors is necessary. In this case, location and weather conditions are not critical when the reference device method is used for outdoor performance measurements. Also, for identical relative SR s, the spectral classification of the simulator is not critical for indoor measurements.
If the performance of a PV device is measured using a known spectral irradiance distribution, its short-circuit current at any other spectral irradiance distribution can be computed using the spectral responsivity of the PV device under test.
| Committee |
CTN 220
|
| DocumentType |
Standard
|
| ISBN |
978-2-8322-7219-0
|
| Pages |
19
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| IEC 60904-7:2019 | Identical |
| EN IEC 60904-7:2019 | Identical |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.